Zobrazeno 1 - 10
of 19
pro vyhledávání: '"Russell J. Swan"'
Autor:
Jeremy J. Kudrna, Tanner J. Ferguson, Russell J. Swan, Steven J. Ferguson, Brandon J. Baartman, Adam R. Bleeker, Ramu G. Sudhagoni, John P. Berdahl, Michael D. Greenwood
Publikováno v:
Ophthalmology and Therapy, Vol 9, Iss 4, Pp 981-992 (2020)
Abstract Introduction This study evaluates the effects of the multi-pressure dial (MPD) on steady-state pattern electroretinography (ss-pERG) parameters. The study is a randomized, controlled, prospective, pilot trial in a private practice setting wi
Externí odkaz:
https://doaj.org/article/2a68dea0a2b741f487c05c1dc0049fdf
Autor:
Tanner J. Ferguson, Catherine G. Knier, Uttio Roy Chowdhury, Kjerseten J. Monson, Michael Greenwood, Russell J. Swan, Richard Gorham, John P. Berdahl, Michael P. Fautsch
Publikováno v:
Ophthalmology and Therapy, Vol 9, Iss 1, Pp 127-137 (2020)
Abstract Purpose To investigate the precision and accuracy of IOP measurements using a pneumatonometer and a tonometer tip cover (Tono-Pen® tip cover) acting as a membrane between a cadaver eye model and pneumatonometer probe. Methods A total of 480
Externí odkaz:
https://doaj.org/article/2e7149b0ff4545e49e5e0dc6c70aa697
Autor:
Vance M. Thompson, Tanner J. Ferguson, Iqbal Ike K. Ahmed, Thomas W. Samuelson, Russell J. Swan, Mitch Ibach, John P. Berdahl
Publikováno v:
Ophthalmology and Therapy, Vol 8, Iss 2, Pp 279-287 (2019)
Abstract Introduction Prospective, open-label, non-randomized, single site study to assess the safety and tolerability of a multi-pressure dial. Methods 30 healthy subjects received application of negative pressure (–15 mmHg) in one eye for 30 minu
Externí odkaz:
https://doaj.org/article/9177fbac0c344bce838229876ae54080
Publikováno v:
Clinical Ophthalmology (Auckland, N.Z.)
Jacob Larsen,1 Travis Whitt,2 Briana Parker,1 Russell Swan3,4 1Clinical Research, Vance Thompson Vision, Bozeman, MT, USA; 2Department of Optometry, Vance Thompson Vision, Bozeman, MT, USA; 3Department of Ophthalmology, Vance Thompson Vision, Bozeman
Autor:
Adam Bleeker, Steven J Ferguson, John P. Berdahl, Tanner J. Ferguson, Jeremy J Kudrna, Michael Greenwood, Russell J Swan, Ramu G Sudhagoni, Brandon J Baartman
Publikováno v:
Ophthalmology and Therapy, Vol 9, Iss 4, Pp 981-992 (2020)
Ophthalmology and Therapy
Ophthalmology and Therapy
Introduction This study evaluates the effects of the multi-pressure dial (MPD) on steady-state pattern electroretinography (ss-pERG) parameters. The study is a randomized, controlled, prospective, pilot trial in a private practice setting with ocular
Autor:
Thomas W. Samuelson, Nathan M. Radcliffe, John P. Berdahl, Russell J Swan, Tanner J. Ferguson, Justin Schweitzer, Richard A. Lewis
Publikováno v:
Clinical Ophthalmology. 13:1947-1953
Purpose To investigate the safety and tolerability of the multi-pressure dial with a continuous 8-hr duration in subjects with open-angle glaucoma. Design Prospective, controlled open-label, randomized, single site study. Subjects Twenty eyes of 10 s
Autor:
Iqbal Ike K. Ahmed, John P. Berdahl, Thomas W. Samuelson, Russell J Swan, Mitch Ibach, Tanner J. Ferguson, Vance Thompson
Publikováno v:
Ophthalmology and Therapy, Vol 8, Iss 2, Pp 279-287 (2019)
Ophthalmology and Therapy
Ophthalmology and Therapy
Introduction Prospective, open-label, non-randomized, single site study to assess the safety and tolerability of a multi-pressure dial. Methods 30 healthy subjects received application of negative pressure (–15 mmHg) in one eye for 30 minutes and a
Autor:
Zachary Dockter, Adam Bleeker, Justin Schweitzer, Russell J Swan, Kayla L. Karpuk, Mitch Ibach, Tanner J. Ferguson, John P. Berdahl
Publikováno v:
Journal of cataract and refractive surgery. 46(9)
To evaluate the long-term safety and efficacy of an iStent trabecular microbypass stent in combination with cataract surgery in pseudoexfoliative glaucoma (PXG).Private practice, Sioux Falls, South Dakota, USA.Retrospective, consecutive case series.E
Autor:
Mitch Ibach, Tanner J. Ferguson, John P. Berdahl, Justin Schweitzer, Russell J Swan, Ramu G Sudhagoni
Publikováno v:
Journal of Glaucoma. 27:71-76
To evaluate the safety and efficacy of a trabecular microbypass stent combined with cataract surgery in patients with severe open-angle glaucoma.The series included 59 eyes with severe primary open-angle glaucoma and severe visual field loss as defin
Autor:
Justin Schweitzer, Mitch Ibach, Tanner J. Ferguson, Ramu G Sudhagoni, Russell J Swan, John P. Berdahl
Publikováno v:
Journal of Cataract and Refractive Surgery. 43:622-626
To evaluate the safety and efficacy of a trabecular microbypass stent (iStent) combined with cataract surgery in patients with pseudoexfoliation glaucoma (PXG).Vance Thompson Vision, Sioux Falls, South Dakota, USA.Retrospective case series.Eyes with