Zobrazeno 1 - 7
of 7
pro vyhledávání: '"Rusong Miao"'
Publikováno v:
Sensors, Vol 20, Iss 11, p 3165 (2020)
Pre-stressed bolted joints are widely used in civil structures and industries. The tightening force of a bolt is crucial to the reliability of the joint connection. Loosening or over-tightening of a bolt may lead to connectors slipping or bolt streng
Externí odkaz:
https://doaj.org/article/e91ed32ee596428691f797db39294a40
New dehumidification system design and dehumidification test for the main cable of suspension bridge
Publikováno v:
Journal of Civil Structural Health Monitoring. 11:1321-1335
To solve the problems of insufficient dry air coverage of the external dry air supply dehumidification system commonly used in the main cable of the suspension bridge, a new dehumidification system is proposed to dehumidify the main cable by deliveri
Publikováno v:
Engineering Failure Analysis. 105:1189-1200
At present, Section integrity hypothesis is mostly used to analyze the mechanical properties and identify the damage of the cable. Based on the actual situation and considering the slip effect between the wires of the cable, two simplified calculatio
Publikováno v:
Sensors, Vol 20, Iss 3165, p 3165 (2020)
Sensors (Basel, Switzerland)
Sensors (Basel, Switzerland)
Pre-stressed bolted joints are widely used in civil structures and industries. The tightening force of a bolt is crucial to the reliability of the joint connection. Loosening or over-tightening of a bolt may lead to connectors slipping or bolt streng
Publikováno v:
Engineering Failure Analysis. 129:105665
Publikováno v:
Journal of Constructional Steel Research. 182:106663
Elastic interaction effect commonly exists in the assembly of multi-bolted joint. It is defined as the loss of tension forces in some bolts due to progressively tightening of neighboring bolts. Main cable clamp is a large size bolted joint used in su
Publikováno v:
Engineering Failure Analysis. 110:104440
In this paper, corrosion fatigue failure of high-strength steel wire was studied based on the actual cable or sling in the bridge, and the service life prediction formula considering the corrosion effect was put forward, which provides a force basis