Zobrazeno 1 - 10
of 16
pro vyhledávání: '"Ruming. Feng"'
Publikováno v:
Frontiers in Built Environment, Vol 10 (2024)
As offshore wind farms move into deeper waters, around 80 m, the high costs necessitate replacing bottom-fixed turbines with floating offshore wind turbines, which require mooring systems to maintain stability within design limits. Data from previous
Externí odkaz:
https://doaj.org/article/c46109eaa43b4d639b51a94730878431
Publikováno v:
Journal of Physics: Conference Series. 2503:012099
This paper establishes a numerical model of wind power generation system. The low voltage ride-through characteristics of direct-driven wind turbines in case of grid failure are studied. By comparing the measured data with the numerical data, the cor
Publikováno v:
Journal of Physics: Conference Series. 2503:012074
This paper proposes a voltage stability index suitable for distributed generation and distribution network which is derived by using the relationship between power balance and voltage balance and the impact of wind power access location, access capac
Publikováno v:
Journal of Physics: Conference Series. 2503:012075
When lightning intrudes into the over-voltage in the 500 kV substation, the lightning wave will be introduced into the substation along the line, which will seriously affect the insulation level of the equipment. In this paper, firstly, the working p
Publikováno v:
Lecture Notes in Electrical Engineering ISBN: 9789811918698
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::36ebd7876d54bc7236a774113020cdaf
https://doi.org/10.1007/978-981-19-1870-4_56
https://doi.org/10.1007/978-981-19-1870-4_56
Publikováno v:
2021 IEEE 2nd China International Youth Conference on Electrical Engineering (CIYCEE).
Publikováno v:
The Proceedings of the 9th Frontier Academic Forum of Electrical Engineering ISBN: 9789813366053
In gas insulated substation (GIS), very fast transient over-voltage (VFTO) is caused during the switching operation because of repeated arc reignition. At present only the first arc is considered for numerical simulation of VFTO, which can’t descri
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::323ae499a279d16046abc9ce3eb344f4
https://doi.org/10.1007/978-981-33-6606-0_34
https://doi.org/10.1007/978-981-33-6606-0_34
Publikováno v:
2020 IEEE 1st China International Youth Conference on Electrical Engineering (CIYCEE).
The accuracy of the arc description of the isolation switch is a key factor affecting the calculation accuracy of the fast transient overvoltage (VFTO). In the current simulation calculation, the commonly used resistance model is equivalent to isolat
Autor:
Taowei Liu, Ruming Feng, Jie Bai, Huijun Wang, Chuanqiang Che, Zheng Kou, Jianli Zhao, Tianyu Liu, Lei Zhao
Publikováno v:
2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE).
Power grid fault will cause the frequency and voltage fluctuation of the nuclear power plant, which will directly affect the operation status of the coolant pump and the heat dissipation blade of the nuclear power unit. When the fluctuation degree ex
Publikováno v:
2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE).
The influence factors of VFTO when the disconnector operating of GIS are obtained, the methods of suppressor VFTO of UHV GIS are put forward. based on construction and operating mode of 550kV GIS VFTO at different operating mode are calculated, the e