Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Rong-Sen Chang"'
Publikováno v:
Measurement Science and Technology. 17:N9-N12
A two-axis tilt sensor, consisting of two lenses and a CMOS image sensor, based on refractive law, is described here. This two-lens optical system, which has a bowl-shaped lens, is designed in such a way that one can find the tilt information for the
Publikováno v:
Thin Solid Films. 466:314-319
The effects of the microstructure and the electrical and optical properties on the formation at highly efficient infrared PtSi Schottky barrier detectors (SBD) have been studied in detail. Two- to twelve-nanometer-thick PtSi films were grown by evapo
Autor:
Rong Sen Chang, Jih Huah Wu
Publikováno v:
SPIE Proceedings.
A low cost, compact electronic image leveler using a CMOS image sensor is developed for level measurement. Optical system with two lenses is designed to get tilt information of total system. One lens is designed in bowl shape that can hold liquid. Th
Autor:
Rong Sen Chang, Jih Huah Wu
Publikováno v:
Novel Optical Systems Design and Optimization VII.
A low cost prototype of a laser range finder using a CMOS image sensor is developed for the automotive field. The system presented here is based on triangulation. The gravity of the infrared laser spot on CMOS image sensor is converted into pixel coo
Publikováno v:
Optical Engineering; Apr2006, Vol. 45 Issue 4, p043603-1-043603-5, 5p
Publikováno v:
Optical Engineering. 45:043603
A low-cost, compact electro-optical leveler, using a CMOS image sensor, has been developed for level measurement. The two-lens optical system is designed to find the tilt information for the total system. ZEMAX is used to design and predict the perfo
Autor:
You-Long Guo, 郭又榮
96
The purpose of developing the new optical triangle measurement system is promoting the measurement precision, minimizing the volume of the old one ; moreover,it can adjust its height and let it become the cheaper and more portable one, which
The purpose of developing the new optical triangle measurement system is promoting the measurement precision, minimizing the volume of the old one ; moreover,it can adjust its height and let it become the cheaper and more portable one, which
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/52692893756456436529
Autor:
Jun-Gi Chen, 陳俊吉
93
There are a lot of measurement methods or equipments for measuring the pulse of human being, including palpation, stethoscope, sphygmomanometer, electrocardiogram (ECG), oximeter, pressure transducer, optical interferometer, Doppler-based ins
There are a lot of measurement methods or equipments for measuring the pulse of human being, including palpation, stethoscope, sphygmomanometer, electrocardiogram (ECG), oximeter, pressure transducer, optical interferometer, Doppler-based ins
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/41831215169452218864
Autor:
Wen-Hsun wang, 王文勳
93
LED(Light Emitting Diode) take advantage of power 、environmental protection、long life time、fast response time (μS) and so on, it will replace the traditional lighting, and become the new light source in the future, so every state have
LED(Light Emitting Diode) take advantage of power 、environmental protection、long life time、fast response time (μS) and so on, it will replace the traditional lighting, and become the new light source in the future, so every state have
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/73159125179128189978
Autor:
Jung-Yi Lin, 林忠毅
96
Traditions zoom lens advance optical axis that continuous zoom mode,Proposed the way is one kind continues the optical axis to change the lens distance,achieves the focal variation function the lens group. The basic work divides into two pa
Traditions zoom lens advance optical axis that continuous zoom mode,Proposed the way is one kind continues the optical axis to change the lens distance,achieves the focal variation function the lens group. The basic work divides into two pa
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/98969537621609231191