Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Ronald D. Rogus"'
Publikováno v:
International Journal of Radiation Oncology*Biology*Physics. 40:245-248
Purpose: To develop a simple equation that can be used to quickly QA check the total treatment time needed for straight or moderately bending, single-catheter implants from the treatment length and dose-prescription depth. A method to quickly check t
Autor:
Ronald D. Rogus, David E. Wazer, Robert G. Zamenhof, Hywel Madoc-Jones, Jacquelyn C. Yanch, Jean-Michel Chabeuf, Guillermo Cano, Sam C. Yam, John A. Bernard, Thomas Dipetrillo, Guido R. Solares, Otto K. Harling
Publikováno v:
Radiation Oncology Investigations. 2:109-118
A team of scientists, engineers and medical researchers from the New England Medical Center (NEMC) and the Massachusetts Institute of Technology's (MIT) Nuclear Reactor Laboratory have been developing Boron Neutron Capture Therapy (BNCT), a binary ra
Autor:
Guido R. Solares, Stephen C. Saris, Clement B. Sledge, John A. Bernard, Damien J. Moulin, Sonya Shortkroff, Ronald D. Rogus, Charles I. Nwanguma, Robert G. Zamenhof, David E. Wazer, Hywel Madoc-Jones, L. Scott Johnson, Ilhan Olmez, Otto K. Harling, Jacquelyn C. Yanch, J. Richard Choi, Stefan Wirdzek
Publikováno v:
Nuclear Science and Engineering. 110:330-348
In this paper, current research in boron neutron capture therapy (BNCT) and radiation synovectomy at the Massachusetts Institute of Technology Research Reactor is reviewed. In the last few years, major emphasis has been placed on the development of B
Publikováno v:
Medical physics. 26(5)
A photogrammetry system designed to reduce simulator-to-treatment and treatment-to-treatment patient positioning errors has been developed. Two complete systems have been installed in our department: one in the simulator room and one in a treatment r
Publikováno v:
Cancer Neutron Capture Therapy ISBN: 9781475795691
An epithermal neutron beam has been developed1,2 for Boron Neutron Capture Therapy (BNCT) at the Massachusetts Institute of Technology Research Reactor (MITR-II). The neutron beam has been used to treat two patients as part of a Phase I clinical tria
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::2a002a047c557ac0d3f880289e765e1c
https://doi.org/10.1007/978-1-4757-9567-7_65
https://doi.org/10.1007/978-1-4757-9567-7_65
Autor:
C. S. Yam, Damien J. Moulin, Ronald D. Rogus, Otto K. Harling, E. L. RedmondII, K. A. Roberts
Publikováno v:
Cancer Neutron Capture Therapy ISBN: 9781475795691
A water-filled head phantom and a wax body part phantom that have been designed for experimental and Monte Carlo based dosimetry for boron neutron capture therapy are described. The head phantom is ellipsoidal, based on the Snyder head model. Body pa
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::5c518af0569128da6ae834eef2d82092
https://doi.org/10.1007/978-1-4757-9567-7_72
https://doi.org/10.1007/978-1-4757-9567-7_72
Publikováno v:
Medical physics. 22(5)
A water-filled head phantom that is designed for use in boron neutron capture therapy is described. The shape of this ellipsoidal phantom, based on the Synder head model, and its composition are designed to simulate the neutron slowing down propertie
Publikováno v:
Medical physics. 21(10)
During the past several years, there has been growing interest in Boron Neutron Capture Therapy (BNCT) using epithermal neutron beams. The dosimetry of these beams is challenging. The incident beam is comprised mostly of epithermal neutrons, but ther
Autor:
David E. Wazer, Sam C. Yam, Frédérique Lambert, Robert G. Zamenhof, Ronald D. Rogus, Otto K. Harling, Jacquelyn C. Yanch, Hywel Madoc-Jones, Guido R. Solares, Jean-Michel Chabeuf
Publikováno v:
Advances in Neutron Capture Therapy ISBN: 9781461362968
The NEMC/MIT group is planning to initiate Phase I clinical trials of BNCT for deep-seated melanoma on the extremities. These trials will be carried out using the epithermal neutron beam at the 5 MW MIT Research Reactor (MITR-II). This paper outlines
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::55560ad88069d677e0d46335c04845a5
https://doi.org/10.1007/978-1-4615-2978-1_150
https://doi.org/10.1007/978-1-4615-2978-1_150
Publikováno v:
Progress in Neutron Capture Therapy for Cancer ISBN: 9781461364948
This paper describes the performance of the currently available epithermal neutron beam at MITR-II. This beam is one of the few clinically useful epithermal neutron beams available for BNCT in the world. The MITR-II epithermal neutron beam has a peak
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::99cf9ec93e743c4bc489525a5790d361
https://doi.org/10.1007/978-1-4615-3384-9_9
https://doi.org/10.1007/978-1-4615-3384-9_9