Zobrazeno 1 - 10
of 24
pro vyhledávání: '"Roger, Bingham"'
Autor:
Wayne, Hoskins, Sophia, Rainbird, Carl, Holder, James, Stoney, Stephen E, Graves, Roger, Bingham
Publikováno v:
Journal of Bone and Joint Surgery. 104:1462-1474
This article was updated on August 17, 2022, because of previous errors, which were discovered after the preliminary version of the article was posted online. On page 1462, in the first sentence of the Abstract section entitled "Results," the phrase
Publikováno v:
The Journal of Arthroplasty. 37:312-315
Background Highly porous-coated titanium acetabular components have a high coefficient of friction and ultraporous surfaces to enhance bone ingrowth and osseointegration in total hip arthroplasty (THA). There have been concerns with the development o
Autor:
Wayne Hoskins, Sophia Corfield, Michelle Lorimer, Yi Peng, Roger Bingham, Stephen E. Graves, Kelly G. Vince
Publikováno v:
The Journal of bone and joint surgery. American volume. 104(17)
When arthroplasty is indicated for a femoral neck fracture (FNF), it is unclear whether total hip arthroplasty (THA) or hemiarthroplasty (HA) is best. This study compares data from the Australian Orthopaedic Association National Joint Replacement Reg
Publikováno v:
Clin Orthop Relat Res
THA is a reasonable surgical option for some patients with fragility fractures of the femoral neck, but it has the risk of prosthesis dislocation. The prosthesis combination that reduces the risk of dislocation and the rate of revision surgery is not
Publikováno v:
Journal of Bone and Joint Surgery. 102:1874-1882
BACKGROUND: A number of surgical approaches are available for total hip arthroplasty (THA), but there are limited large-volume, multi-surgeon data comparing the rates of early revisions following these approaches. The aim of this study was to compare
Publikováno v:
ANZ Journal of Surgery. 90:1299-1302
Background Recently introduced total knee arthroplasty (TKA) implants have been linked with the early development of periprosthetic radiolucency (PPRL). The aim of this study was to carry out a retrospective clinical and radiographical analysis of a
Publikováno v:
The Journal of Arthroplasty. 35:1074-1078
The cementless Corail is one of the most commonly used stems in total hip arthroplasty (THA). The aim of this study was to investigate whether there was a difference in revision rate for smaller stems.All primary THA procedures recorded by the Austra
Publikováno v:
The Journal of bone and joint surgery. American volume. 104(1)
BACKGROUND Compared with other total hip arthroplasty (THA) approaches, the anterior approach has an increased rate of revision for femoral-sided complications, and certain stems may increase this risk. The present study aimed to assess the outcome o
Publikováno v:
Journal of orthopaedic trauma. 36(4)
OBJECTIVE To perform a systematic review and meta-analysis of subtrochanteric femur fractures treated with an intramedullary nail, augmented with or without cerclage wiring, comparing the risk of re-operation, non-union, loss of fixation and implant
Publikováno v:
The Journal of arthroplasty. 36(9)
Background: Dual mobility (DM) and large femoral head bearings (≥36 mm) both decrease the risk of dislocation in total hip arthroplasty (THA). There is limited comparable data in primary THA. This study compared the revision rates for dislocation a