Zobrazeno 1 - 7
of 7
pro vyhledávání: '"Robin Sydney Mackwood Ling"'
Autor:
Graham A. Gie, Robin Sydney Mackwood Ling, Sarah L. Whitehouse, A.J. Clive Lee, A. John Timperley, John Charity
Publikováno v:
The Journal of Arthroplasty. 24:511-517
We present a long-term follow-up report of the results of the original Exeter polished cemented stems inserted between November 1970 and the end of 1975 at our institution by surgeons of widely differing experience using crude cementing techniques. T
Autor:
Ben Squires, Simon C. Lewthwaite, Graham A. Gie, Robin Sydney Mackwood Ling, Andrew John Timperley
Publikováno v:
Clinical orthopaedics and related research. 466(2)
The Exeter Universal hip (Stryker Inc., Newbury, UK) has reported survival rates of 91.74% at 12 years in all patients with reoperation as an endpoint. However, its performance in younger patients has not been fully established. We reviewed survivors
Publikováno v:
The Well-Cemented Total Hip Arthroplasty ISBN: 3540241973
This chapter considers the principles behind the design of cemented femoral stems and concentrates on the issues that are important to the surgeon when selecting a stem for use in clinical practice. Two main issues are central to a surgeon’s choice
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::a7d1295f029bcc1b8781b2d6740820e6
https://doi.org/10.1007/3-540-28924-0_23
https://doi.org/10.1007/3-540-28924-0_23
Publikováno v:
The Well-Cemented Total Hip Arthroplasty ISBN: 3540241973
The first double tapered, polished, collarless, straight femoral stem for cemented total hip arthroplasty (THA) to be used in clinical practice was the Exeter stem, designed in 1969 by Robin Ling and Clive Lee, in Exeter, UK. It has been in use in cl
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::cf4a118c1f6f6b1923cc595d1a7aa36a
https://doi.org/10.1007/3-540-28924-0_30
https://doi.org/10.1007/3-540-28924-0_30
Publikováno v:
The Well-Cemented Total Hip Arthroplasty ISBN: 3540241973
Cemented sockets have provided good long-term outcome with lower overall re-operation rates than cementless designs. Results of cementless sockets implanted with polyethylene liners have been disappointing with increased wear rates and a higher incid
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::c228356344b33ceac1f8752246e71f7f
https://doi.org/10.1007/3-540-28924-0_35
https://doi.org/10.1007/3-540-28924-0_35
Publikováno v:
Scopus-Elsevier
We studied fluid flow at the stem-cement interface of bonded and debonded, polished and rough model femoral components. In a first series of experiments, fluid flow along the interface between bone cement and well-fixed model femoral components, diff
Publikováno v:
Scopus-Elsevier
The influence of operative technique on the formation of incomplete cement mantles in the sagittal plane has been rarely considered in the literature. In this article, we discuss the influence of the anatomy of the proximal femur on the formation of