Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Robert M. Koffsky"'
Publikováno v:
Artificial Organs. 2:257-262
A simple left heart assist device (LHAD) has been developed and employed in nineteen patients with severe left ventricular dysfunction who could not be weaned from cardiopulmonary bypass following intracardiac surgery. It has been used when all other
Autor:
Louis M. Aledort, Howard Shiang, James F Stevenson, Edward F. Leonard, Robert M. Koffsky, Robert S. Litwak, Anthony M. Benis, Hymie L Nossel
Publikováno v:
Thrombosis and Haemostasis. 34:127-144
SummaryFactors determining thrombus formation on a foreign surface were studied with the use of plastic flow chambers introduced into extracorporeal shunts. Silicone rubber shunts, joining the carotid artery and jugular vein, were implanted in dogs a
Autor:
Robert M. Koffsky, Robert S. Litwak, Stephen A. Geller, Fouad A. Lajam, George Silvay, Finn S. Pedersen, Howard Shiang
Publikováno v:
ASAIO Journal. 19:243-250
Publikováno v:
World journal of surgery. 9(1)
Over a decade has elapsed since the first clinical application of our left heart assist device (LHAD). The basic concepts underlying its development evolved from prior experience in which, given adequate support time, less than total left heart bypas
Publikováno v:
92. Kongreß der Deutschen Gesellschaft für Chirurgie, München, 7.–10. Mai 1975 ISBN: 9783540072393
Low cardiac output is a continuing cause of mortality after intracardiac operations in patients coming to surgery with advanced myocardial dysfunction. Intra-aortic balloon counterpulsation (IABC) may be effective in improving the hemodynamic state o
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::b9515a11a8974afdf9d9a0f7293cbb36
https://doi.org/10.1007/978-3-662-05557-1_17
https://doi.org/10.1007/978-3-662-05557-1_17
Autor:
Robert S. Litwak, Roy A. Jurado, Adam Fischer, George Silvay, James J. Sherman, Lukban Sb, Robert M. Koffsky, Fouad A. Lajam, Arcadio F. Ortiz
Publikováno v:
The Annals of thoracic surgery. 21(3)
A left heart assist device (LHAD) has been employed in 14 patients. All had advanced heart disease and were in low cardiac output after repair, such that they could not be separated from cardiopulmonary bypass despite prolonged support and adjuvant t
Publikováno v:
Annals of biomedical engineering. 3(3)
The interaction of artificial materials with the process of thrombus formation in blood depends on geometric and fluid-mechanical factors as well as the proximity of even slightly injured tissue. A test device that takes account of these factors and
Autor:
Robert S. Litwak, Roy A. Jurado, Russell W. Brancato, Fouad A. Lajam, Robert M. Koffsky, Lukban Sb, Samuel K. Elster
Publikováno v:
The New England journal of medicine. 291(25)
IN recent years there has been a steady decline in mortality after open intracardiac operations. However, persistent low cardiac output remains one of the prime causes of death, particularly in patients with far advanced myocardial dysfunction at the
Publikováno v:
Critical Care Medicine. 1:117