Zobrazeno 1 - 10
of 36
pro vyhledávání: '"Robert H. Zeff"'
Publikováno v:
ASAIO Journal. 39:M204-M207
A small wave propagation pump (WPP) was incorporated into oxygenators to create a disposable heart-lung machine. The WPP provides undirectional micropulsatile laminar flow of 8 L/min against 800 mmHg. The smaller WPP can generate 4 L/min against 400
Autor:
Steven J. Phillips, Chamnahn Kongtahworn, Robert H. Zeff, James R. Skinner, Basaviah Chandramouli, John H. Gay
Publikováno v:
The Annals of Thoracic Surgery. 49:734-739
Six infants with total anomalous pulmonary venous connection below the diaphragm had correction by modification of conventional surgical technique. Catheterization revealed the confluence of the pulmonary veins draining into a descending vein below t
Autor:
Lawrence Barker, Robert H. Zeff, André Grignon, Margaret H. Verhey, Steven J. Phillips, William J. Wickemeyer, Mark A. Tannenbaum, Chamnahn Kongtahworn, L.A. Iannone, David F. Gordon, Magdi Ghali
Publikováno v:
The Annals of thoracic surgery. 54(5)
Sixteen patients (2 women, 14 men) aged 29 to 72 years with continued cardiogenic shock during intraaortic balloon pumping (IABP) had additional treatment with percutaneous cardiopulmonary bypass (PBY). Cause of cardiogenic shock was myocardial infar
Autor:
Robert H. Zeff, Magdi Ghali, L.A. Iannone, Chamnahn Kongtahworn, Mark A. Tannenbaum, Steven J. Phillips
Publikováno v:
The Annals of thoracic surgery. 53(1)
A technique is described that allows insertion of a standard percutaneous intraaortic balloon without use of the larger 12F sheath. Standard 9.5-cm. Percor balloons were inserted in a series of patients without using the provided sheath. Elimination
Autor:
Mark McGaughey, Edward Ong, T.M. Brown, Chris Sanchez, Steven J. Phillips, John Glotzer, John Thelin, Robert H. Zeff, Mark Spector, David Gordon, Linda Anania, Michael Pester
Publikováno v:
Journal of the American College of Cardiology. 15(2)
Autor:
Robert H. Zeff, James R. Skinner, Chamnahn Kongtahworn, Vasanth B. Solomon, Richard S. Toon, Christopher Rasak, Steven J. Phillips
Publikováno v:
The Annals of Thoracic Surgery. 38:42-45
Forty-one patients underwent resection of a postinfarction ventricular aneurysm. Thirty-seven of them had associated saphenous vein grafting procedures (average, 2.3 grafts per patient). Thirty-five patients sustained left ventricular dysfunction pre
Autor:
L.A. Iannone, André Grignon, Mark Spector, Steven J. Phillips, James R. Skinner, Robert H. Zeff, Richard S. Toon, Chamnahn Kongtahworn
Publikováno v:
The Annals of Thoracic Surgery. 47:880-883
Of 2,859 patients having percutaneous transluminal coronary angioplasty, 201 (7%) underwent emergency coronary artery bypass grafting. Two categories of patients were reviewed. Group 1 consisted of 126 patients of 2, 304 who had immediate coronary ar
Publikováno v:
The Journal of Thoracic and Cardiovascular Surgery. 86:679-688
Between 1975 and 1982, 339 patients underwent emergency coronary artery reperfusion for treatment of evolving myocardial infarction (MI). Group I (112 patients) had reperfusion with intracoronary streptokinase. Group II (46 patients) had reperfusion
Autor:
Teiko P, Isom Ow, Alfred T. Culliford, Joseph N. Cunningham, Frank C. Spencer, Robert H. Zeff
Publikováno v:
The Journal of Thoracic and Cardiovascular Surgery. 72:714-726
From a series of 2,594 patients undergoing open-heart surgery, 39 had sternal or costochondral infections. Most of these infections were associated with a number of predisposing factors: prolonged perfusion time, excessive postoperative bleeding, dep
Autor:
Iannone La, Robert H. Zeff, Gordon Df, C Kongtahworn, Brown Tm, Kreamer R, Steven J. Phillips
Publikováno v:
ASAIO Journal. 25:186-191
A permanent parallel aortic pump (PAP), essentially a permanent intra-aortic balloon pump or modified dynamic aortic patch, has been designed to support failing left ventricles The PAP is a counterpulsation system in which an external energy source d