Zobrazeno 1 - 10
of 51
pro vyhledávání: '"Robert G. Waggener"'
Autor:
Melissa M. Blough, William D. McDavid, Sean Zhang, Nina E. Lee, James A. Terry, Di Chen, Robert G. Waggener
Publikováno v:
Medical Physics. 26:1269-1278
Attenuation measurements for primary x-ray spectra from 25 kVp to 18 MV were made using aluminum filters for all energies except for orthovoltage where copper filters were used. An iterative perturbation method, which utilized these measurements, was
Publikováno v:
Journal of X-ray science and technology. 17(1)
Megavoltage X-ray sources are commonly used for therapy planning, and knowledge of their spectral distribution is important for accurate dose calculations. There are many methods that could provide reasonable estimations of Megavoltage X-ray spectra,
Publikováno v:
Medical physics. 26(6)
A multihole diverging Cerrobend plug for megavoltage energies was used to measure water transmission values at different locations in a 20×20 cm field at 100 cm source-to-axis distance (SAD) for 4, 6, and 15 MV therapy photon beams. The transmission
Publikováno v:
Medical physics. 26(2)
Differences in half-value layer (HVL) and radiation intensity are investigated as a function of position in the mammographic radiation field. Sources of systematic variation include the heel effect, the inverse square law, and differential photon pat
Publikováno v:
Medical physics. 25(9)
A model for calculating mammographic spectra independent of measured data and fitting parameters is presented. This model is based on first principles. Spectra were calculated using various target and filter combinations such as molybdenum/molybdenum
Publikováno v:
Physics in medicine and biology. 37(12)
A variable Jacobian and weighted backprojection algorithm, used for medical CT, was adapted to perform CT reconstructions on data obtained with a dental panoramic x-ray unit. A detector array, fitted to the unit for the purpose of acquiring digital p
Autor:
Joseph S. Blinick, Edward L. Nickoloff, Mitchell G. Randall, Mary E. Moore, G. Donald Frey, Robert Y. L. Chu, Priscilla F. Butler, James V. Atherton, Lance V. Hefner, Joel E. Gray, Stephen Balter, Robert G. Waggener, Louis K. Wagner
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::028b0cd15a75a27b3cb0b1a59afe0aa9
https://doi.org/10.37206/32
https://doi.org/10.37206/32
Publikováno v:
Medical Physics. 34:2409-2409
Purpose: To propose a novel reconstruction algorithm which is accurate even for transmitted data affected by the usual experimental error, and therefore can be used in a typical clinical environment. Method and Materials:Ionization chamber and radiol
Autor:
Tony Yuen Eng, Charles R. Thomas, Carlos Esquivel, Martin L. Meltz, Clifton D. Fuller, Melissa M. Blough, Robert G. Waggener, Adrian Wong
Publikováno v:
Radiation Oncology (London, England)
Radiation Oncology, Vol 1, Iss 1, p 36 (2006)
Radiation Oncology, Vol 1, Iss 1, p 36 (2006)
Background Treatment of choroidal melanoma with radiation often involves placement of customized brachytherapy eye-plaques. However, the dosimetric properties inherent in source-based radiotherapy preclude facile dose optimization to critical ocular
Publikováno v:
Medical Physics. 33:2016-2016
Purpose: To determine diagnostic x‐ray photon spectra using simple transmission measurements.Method and Materials: A database of measured and calculated x‐ray photon spectra values from the Catalogue of Spectral Data for Diagnostic X‐rays, R. B