Zobrazeno 1 - 10
of 42
pro vyhledávání: '"Robert Di Paola"'
Autor:
Robert Di Paola, Heriberto Bruzzoni-Giovanelli, Frdrique Frouin, Edmond Kahn, Catherine Souchier, Olivier Clment, Fabien Calvo, Jean-Claude Bernengo, Guy Frija, G Linares-Cruz
Publikováno v:
Cytometry. 40:42-49
Background: The aims of this study were (1) to realign cellular preparations when spots and structures are excited by different lasers of a confocal laser scanning microscope (multilaser studies); (2) to avoid the use of realigment methods by selecti
Publikováno v:
Medical Physics. 22:381-390
This paper presents a computerized method for the automated segmentation of individual microcalcifications in a region of interest (ROI) known to contain a cluster in digital mammograms. Mammographic parenchyma caj be accurately modeled with the frac
Publikováno v:
Medical Physics. 21:1865-1874
A simulation model of clustered microcalcifications superimposed on normal mammographic backgrounds has been developed and evaluated. A cluster is described according to its size, the number of microcalcifications it contains, and their density. A mi
Publikováno v:
Computerized Medical Imaging and Graphics. 16:81-91
An increased number of image sequences is acquired in all modalities of the biomedical imaging field in order to study displacement or metabolism of a tracer or a contrast agent. It requires effective processing methods to estimate the underlying phy
Autor:
Habib Benali, Jean-Marc Guinebretiere, Jean-François Moreau, Joël Chabriais, Alvian Lesnik, Robert Di Paola
Publikováno v:
Academic Radiology. 3:S248-S250
Publikováno v:
Physics in medicine and biology. 46(5)
Tc methoxyisobutylisonitrile planar scintimammography (SMM) is mostly performed using low-energy high-resolution (LEHR) parallel collimators. We studied whether using a different collimator could improve the detection of small (
Publikováno v:
Medical Imaging 1999: PACS Design and Evaluation: Engineering and Clinical Issues.
Currently, various data formats are widely used for medical imags, e.g. DICOM for exchange through network and storage media, and INTERFILE for image exchange in nuclear medicine. These formats are only able partly to solve problems arising in access
Autor:
Andrew Todd-Pokropek, Habib Benali, Celine Huguenin, Florent Aubry, Virginie Chameroy, Robert Di Paola, Irène Buvat
Publikováno v:
Medical Imaging 1999: Image Display.
In medical imaging, many methods of irreversible compression have been studied. However, none of them has been adopted as a standard, probably because of the lack of agreement regarding what is meant by 'acceptable' for an irreversible compression sc
Autor:
M. Pélégrini, Florent Aubry, Georges El Fakhri, Irène Buvat, Habib Benali, Andrew Todd-Pokropek, Virginie Chameroy, Robert Di Paola, Celine Huguenin
Publikováno v:
Medical Imaging: Image Processing
Evaluations of procedures in medical image processing are notoriously difficult and often unconvincing. From a detailed bibliographic study, we analyzed the way evaluation studies are conducted and extracted a number of entities common to any evaluat
Publikováno v:
Medical Image Databases ISBN: 9781461375395
Medical imaging data carry information which may be morphological or functional, and qualitative (e.g., labelling of zones) or quantitative (e.g., model identification). This information may be used in clinical practice or in fundamental, clinical or
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::b94cfa2432446d7b96a7b4cb32817181
https://doi.org/10.1007/978-1-4615-5553-7_6
https://doi.org/10.1007/978-1-4615-5553-7_6