Zobrazeno 1 - 10
of 74
pro vyhledávání: '"Robert B Leman"'
Autor:
Anbukarasi Maran, Ashley Waring, J. Madison Hyer, David D. Daly, Michael R. Gold, J. Lacy Sturdivant, Frank Cuoco, Robert B. Leman, Frederick W. Funke
Publikováno v:
Pacing and Clinical Electrophysiology. 39:863-869
Background Cardiac resynchronization therapy (CRT) improves functional status, reduces heart failure hospitalizations, and decreases mortality. Several comorbidities including renal function affect outcomes with CRT. However, moderate to severe chron
Publikováno v:
Journal of Cardiovascular Electrophysiology. 25:624-630
Effect of QLV on CRT Hemodynamic Response Introduction Cardiac resynchronization therapy (CRT) improves hemodynamic function, as well as reduces hospitalizations and mortality among patients with systolic dysfunction, QRS prolongation, and heart fail
Autor:
William W. Brabham, J. Lacy Sturdivant, J. Marcus Wharton, Darren S. Sidney, Michael R. Gold, Christopher P. Rowley, Robert B. Leman, Peter C. Netzler, Michael L. Bernard, Frank Cuoco
Publikováno v:
The American Journal of Cardiology. 111:1165-1168
The perioperative bleeding risk associated with therapeutic anticoagulation at cardiac implantable electronic device implantation has previously been demonstrated to vary by the specific anticoagulant used. Although uninterrupted anticoagulation with
Autor:
David D, Daly, Anbukarasi, Maran, J Madison, Hyer, Frederick, Funke, Ashley, Waring, Frank A, Cuoco, J Lacy, Sturdivant, Robert B, Leman, Michael R, Gold
Publikováno v:
Pacing and clinical electrophysiology : PACE. 39(8)
Cardiac resynchronization therapy (CRT) improves functional status, reduces heart failure hospitalizations, and decreases mortality. Several comorbidities including renal function affect outcomes with CRT. However, moderate to severe chronic kidney d
Autor:
Matthew S. Forcina, Robert H. Yoe, William H. Spencer, Michael R. Gold, Valerian L. Fernandes, Jason B. Coker, Christopher D. Nielsen, Robert B. Leman, J. Marcus Wharton, J. Lacy Sturdivant, Ernest M. Quin, Frank A. Cuoco
Publikováno v:
Journal of Cardiovascular Electrophysiology. 22:569-572
Defibrillation Thresholds in Hypertrophic Cardiomyopathy. Background: Defibrillation threshold (DFT) testing is performed in part to ensure an adequate safety margin for the termination of spontaneous ventricular arrhythmias. Left ventricular mass is
Randomized comparison of defibrillation thresholds from the right ventricular apex and outflow tract
Autor:
Michael R. Gold, J. Marcus Wharton, Frank Cuoco, Carl R. Reynolds, Robert B. Leman, Vladimir P. Nikolski, J. Lacy Sturdivant
Publikováno v:
Heart Rhythm. 7:1561-1566
Background Implantable cardioverter-defibrillator (ICD) leads are traditionally placed in the right ventricular apex (RVA), in part because this is considered the preferred vector for minimizing defibrillation threshold (DFT). However, if adequate DF
Autor:
Michael R. Gold, John Lacy Sturdivant, Jiang Ding, Douglas R. Daum, Michael C. Giudici, Michael H. Kim, Yinghong Yu, Shantha Arcot-Krishnamurthy, Robert B. Leman, Alan D. Waggoner, Imran Niazi
Publikováno v:
Journal of Cardiovascular Electrophysiology. 20:894-900
Chronotropic incompetence is common among patients with advanced heart failure (HF), thus atrial pacing (AP) is frequently utilized in this population. The hemodynamic effects of AP during cardiac resynchronization therapy (CRT) have not been well st
Autor:
Jennifer Garry, Lacy J. Sturdivant, Elizabeth Clarke, Robert B. Leman, Nancy J. Finch, Tammy Barnes, Michael R. Gold, Eva R. Serber
Publikováno v:
Pacing and Clinical Electrophysiology. 32:383-390
Background: The implantable cardioverter-defibrillator (ICD) is the established treatment for patients with a history of or at risk for sudden cardiac arrest. Patients receiving an ICD are diverse, and little is known regarding their preferences for
Publikováno v:
Pacing and Clinical Electrophysiology. 32:24-28
Introduction: High defibrillation threshold (DFT) with an inadequate defibrillation safety margin remains an infrequent but troubling problem associated with defibrillator implantation. Dofetilide is a selective class III antiarrhythmic drug that red
Autor:
William H. Spencer, J. Marcus Wharton, Michael R. Gold, J. Lacy Sturdivant, Frank Cuoco, Valerian Fernandes, Sherif F. Nagueh, Christopher D. Nielsen, Robert B. Leman
Publikováno v:
Journal of the American College of Cardiology. 52(21):1718-1723
Objectives The purpose of this study was to examine the effects of alcohol septal ablation (ASA) on ventricular arrhythmias among patients with obstructive hypertrophic cardiomyopathy (HCM), as measured by appropriate implantable cardioverter-defibri