Publikováno v:
Medical Physics. 29:311-318
Multiframe quantitative coronary angiography is typically performed by averaging measurements of artery diameter over multiple frames. This approach reduces errors attributable to random noise but may not reduce systematic errors caused by background
Publikováno v:
Computer Aided Surgery. 7:84-89
Publikováno v:
IEEE Transactions on Medical Imaging. 20:990-998
Layer decomposition is a promising method for obtaining accurate densitometric profiles of diseased coronary artery segments. This method decomposes coronary angiographic image sequences into moving densitometric layers undergoing translation, rotati
Publikováno v:
The Journal of the Institute of Image Information and Television Engineers. 53:449-457
In the conventional gradient method of optical flow the movement of an object is estimated by a bottom-up algorithm starting from local processing. However, the method cannot be applied to the large displacement of the object. Many methods have been
Publikováno v:
Medical Physics. 23:133-139
A novel method is presented for correcting errors in measurements of biplane projection imaging geometry without prior identification of corresponding points in the two images. For imaged objects that project onto both images, a constraint equation i
Publikováno v:
IIH-MSP
One of the representative methods of optical flow is a gradient method which estimates the movement of an object based on the differential of image brightness. However, the method is ineffective for large displacement of the object and many improved
Publikováno v:
International Journal for Parasitology. 21:479-482
The geographic distributions of alleles at 11 gene loci in Heterodoxus octoseriatus were examined and found not to be random. Rather, there were at least two geographic patterns, one of which mirrored approximately the geographic ranges of the hosts
Publikováno v:
Medical Imaging: Image-Guided Procedures
Display stabilization is a technique by which a feature of interest in a cine image sequence is tracked and then shifted to remain approximately stationary on the display device. Prior simulations indicate that display stabilization with high playbac
Publikováno v:
SPIE Proceedings.
Fluoroscopic images are degraded by scattering of x-rays from within the patient and by veiling glare in the image intensifier. Both of these degradations are well described by a response function applied to primary intensity. We can automatically es
Publikováno v:
Medical Imaging: Image Processing
Layer decomposition is a promising technique for background removal and noise reduction in coronary angiograms. Our layer decomposition algorithm decomposes a projection image sequence into multiple 2D layers undergoing translation, rotation, and sca