Zobrazeno 1 - 10
of 17
pro vyhledávání: '"Reza Atashkhooei"'
Autor:
Adam Quotb, Reza Atashkhooei, Simone Magaletti, Francis Jayat, Clement Tronche, Julien Goechnahts, Julien Perchoux
Publikováno v:
Sensors, Vol 21, Iss 4, p 1300 (2021)
At the micrometric scale, vessels or skin capillaries network architecture can provide useful information for human health management. In this paper, from simulation to in vitro, we investigate some limits and interests of optical feedback interferom
Externí odkaz:
https://doaj.org/article/38a0116beb5f44a798f08df9f178fab3
Publikováno v:
Sensors, Vol 16, Iss 7, p 997 (2016)
Microcantilever motion detection is a useful tool for the characterization of the physical, chemical and biological properties of materials. In the past, different approaches have been proposed and tested to enhance the behavior, size and simplicity
Externí odkaz:
https://doaj.org/article/6a41b42d0c8e4991bf634e2e08fced35
Autor:
Julien Perchoux, Adam Quotb, Reza Atashkhooei, Francisco J. Azcona, Evelio E. Ramírez-Miquet, Olivier Bernal, Ajit Jha, Antonio Luna-Arriaga, Carlos Yanez, Jesus Caum, Thierry Bosch, Santiago Royo
Publikováno v:
Sensors, Vol 16, Iss 5, p 694 (2016)
Optical feedback interferometry (OFI) sensors are experiencing a consistent increase in their applications to biosensing due to their contactless nature, low cost and compactness, features that fit very well with current biophotonics research and mar
Externí odkaz:
https://doaj.org/article/6080724c9da141dd840a978048f8cb8b
Autor:
Adam Quotb, Reza Atashkhooei, Raul da Costa Moreira, Evelio E. Ramírez-Miquet, Santiago Royo, Julien Perchoux
Publikováno v:
IEEE Sensors Journal
IEEE Sensors Journal, Institute of Electrical and Electronics Engineers, 2018, 18 (4), pp.1457-1463. ⟨10.1109/JSEN.2017.2781902⟩
IEEE Sensors Journal, 2018, 18 (4), pp.1457-1463. ⟨10.1109/JSEN.2017.2781902⟩
Recercat. Dipósit de la Recerca de Catalunya
instname
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
IEEE Sensors Journal, Institute of Electrical and Electronics Engineers, 2018, 18 (4), pp.1457-1463. ⟨10.1109/JSEN.2017.2781902⟩
IEEE Sensors Journal, 2018, 18 (4), pp.1457-1463. ⟨10.1109/JSEN.2017.2781902⟩
Recercat. Dipósit de la Recerca de Catalunya
instname
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
International audience; Optical feedback interferometry (OFI) based flowmetry enables simple, robust, self-aligned and low cost systems to measure the fluid flow velocity with reasonable accuracy. The particle concentration in the fluid causes signif
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2891fc7cec093165ce6f9077bdefdf29
https://hal.archives-ouvertes.fr/hal-01685176
https://hal.archives-ouvertes.fr/hal-01685176
Publikováno v:
Recercat. Dipósit de la Recerca de Catalunya
instname
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
instname
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
We propose differential optical feedback interferometry, a technique able to measure nanometer-size amplitude displacements by comparing the optical power of two lasers subject to optical feedback. In this letter, the principles of the technique are
Publikováno v:
Recercat. Dipósit de la Recerca de Catalunya
Universitat Jaume I
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
Universitat Jaume I
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
Abstract—Demagnetization faults have a negative impact on the behavior of permanent-magnet synchronous machines, thus reducing their efficiency, generating torque ripple, mechanical vibrations, and acoustic noise, among others. In this paper, the d
Autor:
Antonio Luna-Arriaga, Carlos Yáñez, Julien Perchoux, Jesus Caum, Francisco J. Azcona, Evelio E. Ramírez-Miquet, Adam Quotb, Reza Atashkhooei, Thierry Bosch, Olivier D. Bernal, Santiago Royo, Ajit Jha
Publikováno v:
Sensors; Volume 16; Issue 5; Pages: 694
Recercat. Dipósit de la Recerca de Catalunya
instname
Sensors, Vol 16, Iss 5, p 694 (2016)
Sensors
Sensors, MDPI, 2016, 16 (5), pp.694. ⟨10.3390/s16050694⟩
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
Sensors (Basel, Switzerland)
Sensors, 2016, 16 (5), pp.694. ⟨10.3390/s16050694⟩
Recercat. Dipósit de la Recerca de Catalunya
instname
Sensors, Vol 16, Iss 5, p 694 (2016)
Sensors
Sensors, MDPI, 2016, 16 (5), pp.694. ⟨10.3390/s16050694⟩
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
Sensors (Basel, Switzerland)
Sensors, 2016, 16 (5), pp.694. ⟨10.3390/s16050694⟩
International audience; Optical feedback interferometry (OFI) sensors are experiencing a consistent increase in their applications to biosensing due to their contactless nature, low cost and compactness, features that fit very well with current bioph
Publikováno v:
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
Sensors (Basel, Switzerland)
Sensors, Vol 16, Iss 7, p 997 (2016)
Sensors; Volume 16; Issue 7; Pages: 997
Recercat. Dipósit de la Recerca de Catalunya
instname
Universitat Politècnica de Catalunya (UPC)
Sensors (Basel, Switzerland)
Sensors, Vol 16, Iss 7, p 997 (2016)
Sensors; Volume 16; Issue 7; Pages: 997
Recercat. Dipósit de la Recerca de Catalunya
instname
Microcantilever motion detection is a useful tool for the characterization of the physical, chemical and biological properties of materials. In the past, different approaches have been proposed and tested to enhance the behavior, size and simplicity
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::3c1cad21656731050cb2a62b0274eccd
http://hdl.handle.net/2117/90027
http://hdl.handle.net/2117/90027
Autor:
Lucie Campagnolo, Thierry Camps, Julien Perchoux, Yu Zhao, Reza Atashkhooei, Véronique Bardinal
Publikováno v:
Optics Express
Optics Express, Optical Society of America-OSA Publishing, 2016, 24 (21), pp.23849-23849. ⟨10.1364/OE.24.023849⟩
Optics Express, 2016, 24 (21), pp.23849-23849. ⟨10.1364/OE.24.023849⟩
Optics Express, Optical Society of America-OSA Publishing, 2016, 24 (21), pp.23849-23849. ⟨10.1364/OE.24.023849⟩
Optics Express, 2016, 24 (21), pp.23849-23849. ⟨10.1364/OE.24.023849⟩
International audience; Optical feedback interferometry (OFI) performance for microscale-flow sensing is studied theoretically and experimentally. A new numerical modeling approach for OFI flow meter spectrum reproduction is presented in this work to
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::3113a9d3ebe863fbb818bc5d18c0d533
https://hal.laas.fr/hal-01446494/document
https://hal.laas.fr/hal-01446494/document
Publikováno v:
Recercat. Dipósit de la Recerca de Catalunya
Universitat Jaume I
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
Universitat Jaume I
UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
In this paper, a self-mixing interferometry sensor has been used as a proximity probe to measure possible runout in permanent magnet synchronous motors, for fault diagnosis. A general procedure for the measurement of the 2-D trajectory of the motor s
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8a847eb1d15758350bf0ead6ed2886de
https://hdl.handle.net/2117/21890
https://hdl.handle.net/2117/21890