Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Regina K. Fulkerson"'
Autor:
Jose Perez-Calatayud, Facundo Ballester, Yury Niatsetski, Bruce R. Thomadsen, Frank André Siebert, Yongbok Kim, Frank Weigand, Ivan Buzurovic, Regina K. Fulkerson, Mark J. Rivard, Zoubir Ouhib, Sujatha Pai, Yi Rong
Publikováno v:
Medical physicsREFERENCES. 47(10)
The surface brachytherapy Task Group report number 253 discusses the common treatment modalities and applicators typically used to treat lesions on the body surface. Details of commissioning and calibration of the applicators and systems are discusse
Autor:
Regina K. Fulkerson
Publikováno v:
Medical Physics. 43:2005-2006
Publikováno v:
Physics in medicine and biology. 59(6)
This paper describes the development and characterization of a fully automated in vitro cell irradiator using an electronic brachytherapy source to perform radiation sensitivity bioassays. This novel irradiator allows complex variable dose and dose r
Publikováno v:
Medical physics. 41(2)
Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with spec
Publikováno v:
Medical physics. 41(2)
Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with spec
Publikováno v:
Medical Physics. 41:022103
Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions
Publikováno v:
Medical Physics. 41:022104
Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions
Publikováno v:
Medical Physics. 40:071732
Purpose: Pulsed-dose-rate (PDR) brachytherapy was originally proposed to combine the therapeutic advantages of high-dose-rate (HDR) and low-dose-rate brachytherapy. Though uncommon in the United States, several facilities employ pulsed-dose-rate brac
Publikováno v:
Medical Physics. 40:552-552
Purpose : Modern biology research often depends upon high‐throughput assays that are incompatible with traditional irradiation techniques due to dose inhomogeneity and dose rate limitations of the most common irradiator systems. To overcome these l
Publikováno v:
Medical Physics. 39:3804-3804
Purpose: Conical brachytherapysurface applicators with diameters ranging from 10 mm to 45 mm have been developed by Varian Medical Systems, Inc. These applicators are designed to be used with the GammaMedplus iX and VariSource iX high‐dose rate Ir