Zobrazeno 1 - 10
of 21
pro vyhledávání: '"Ray Fairbend"'
Autor:
Charlotte F. Feldman, Richard Willingale, James F. Pearson, Gillian Butcher, Philip Peterson, Tony Crawford, Paul Houghton, Roisin Speight, Alexander Lodge, Christopher Bicknell, Julian P. Osborne, Paul O'Brien, Miranda Bradshaw, Vadim Burwitz, Gisela Hartner, Andreas Langmeier, Thomas Müller, Surangkhana Rukdee, Thomas Schmidt, Diego Götz, Karine Mercier, Jean-Michel Le Duigou, François Gonzalez, Emile Schyns, Romain Roudot, Ray Fairbend, Julien Seguy
Publikováno v:
Space Telescopes and Instrumentation 2022: Ultraviolet to Gamma Ray.
Autor:
Emile Schyns, Ray Fairbend, Melissa McHugh, Alexander Lodge, Ian Hutchinson, Charlotte Feldman, Julien Seguy, Romain Roudot, Hannah Natasha Lerman, P. T. O'Brien, Roisin Speight, Richard Willingale
The Transient High Energy Sources and Early Universe Surveyor is an ESA M5 candidate mission currently in Phase A, with Launch in $\sim$2032. The aim of the mission is to complete a Gamma Ray Burst survey and monitor transient X-ray events. The Unive
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e444f2111d2ca33be87d2050e24e9173
Autor:
Gillian Butcher, Adrian Martindale, Ray Fairbend, Emma J. Bunce, Charlotte Feldman, James F. Pearson, Richard Willingale, Emile Schyns
Publikováno v:
Space Telescopes and Instrumentation 2018: Ultraviolet to Gamma Ray.
We report on the design, development and measured performance of the Microchannel plate X-ray optics for the Mercury imaging X-ray spectrometer instrument, due to fly to Mercury on the ESA/JAXA BepiColombo mission in 2018. This paper serves as a prog
Autor:
Pascal Blanquer, Stefan Kraft, Roland Graue, Kotska Wallace, Maximilien J. Collon, Julien Seguy, Marcos Bavdaz, Marco W. Beijersbergen, D. Kampf, Ray Fairbend
Publikováno v:
International Conference on Space Optics — ICSO 2006.
In support of future x-ray telescopes ESA is developing new optics for the x-ray regime. To date, mass and volume have made x-ray imaging technology prohibitive to planetary remote sensing imaging missions. And although highly successful, the mirror
Autor:
Paul Drumm, Jean-Michel Le Duigou, James F. Pearson, Charlotte Feldman, Emile Schyns, Diego Götz, Richard Willingale, Adrian Martindale, Paul Houghton, Chris Bicknell, J. P. Osborne, Romain Roudot, P. T. O'Brien, Sylvain Petit, Ray Fairbend, K. Mercier, John Sykes
Publikováno v:
Optics for EUV, X-Ray, and Gamma-Ray Astronomy VIII.
This research used the SPECTRE High Performance Computing Facility at the University of Leicester.
Autor:
Ray Fairbend, J. P. Osborne, P. T. O'Brien, Richard Willingale, James F. Pearson, Emile Schyns, C. Feldman, Adrian Martindale, S. Petit
Publikováno v:
Space Telescopes and Instrumentation 2016: Ultraviolet to Gamma Ray
We identify all the significant aberrations that limit the performance of square pore micro-channel plate optics (MPOs) used as an X-ray lobster eye. These include aberrations intrinsic to the geometry, intrinsic errors associated with the slumping p
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 573:232-235
Modern microchannel plate detectors exhibit low quantum efficiency in the extreme ultra violet range compared to those manufactured before 1990. The cause of this reduction in efficiency is unknown. We describe recent investigations into the along-ch
Autor:
Anthony J. Peacock, G.W. Fraser, Gareth J Price, Marcos Bavdaz, Marco W. Beijersbergen, J.-P. Boutot, Enrico Tomaselli, Sven Olof Flyckt, Ray Fairbend, Adam N. Brunton
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 490:276-289
Square-pore microchannel plate (MCP) X-ray optics of the “lobster-eye” geometry have frequently been described in the literature. We have now investigated the use of a radial channel packing geometry which, in the context of an MCP pair slumped t
Autor:
Marco W. Beijersbergen, Sven Olof Flyckt, George W. Fraser, Enrico Tomaselli, Anthony J. Peacock, Adam N. Brunton, Gareth J Price, J.-P. Boutot, Ray Fairbend, Marcos Bavdaz
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 490:290-298
We investigate, by ray-trace simulation, two hard X-ray telescopes based on microchannel plate (MCP) optics. The first is the, by now well known, lobster-eye geometry, while the second is a novel design. The second design uses a pair of MCPs with squ
Autor:
J Benkoff, James Carpenter, Andrew Bradley, C Brown, Emma J. Bunce, Mark L. Prydderch, Ray Fairbend, G.W. Fraser, Peter Lechner, E. Sclater, T Jorden, Martin Hilchenbach, G. Lutz, Jyri Näränen, Juhani Huovelin, Johannes Treis, Philip A. Bland, David A. Rothery, M. Syrjasuo, D. L. Talboys, C. H. Whitford, S. Hermann, F. Giannini, James F. Pearson, Adrian Martindale, M Ashcroft, M Hesse, A Bowyer, M. Anttila, M Feasey, P. Portin, Mahesh Anand, I Kitchingman, Emile Schyns, John Bridges, Matti Kaipiainen, Lothar Strüder, T. Stevenson, M Evans, J San Juan, S. Whitehead, Ulrich R. Christensen, C. Bulloch, Karri Muinonen, A. Malkki, Katherine H. Joy, P Thomas
The Mercury Imaging X-ray Spectrometer (MIXS) on the BepiColombo Mercury Planetary Orbiter (MPO), will measure fluorescent X-ray emission from the surface of Mercury in the energy range 0.5 – 7.5 keV, which is induced by incident solar X-rays and s
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::3a14e8eaffd7e9ab99e04ccc6a2d1ff2
http://oro.open.ac.uk/16347/1/Fraser_et_al.pdf
http://oro.open.ac.uk/16347/1/Fraser_et_al.pdf