Zobrazeno 1 - 10
of 44
pro vyhledávání: '"Randall A. Allardyce"'
Autor:
John W. Pickering, D. O. McGregor, Malina K. Storer, Jenny Scotter, Randall A. Allardyce, Zoltan H. Endre, Wan-Ping Hu, Katherine T. Moorhead
Publikováno v:
Physiological Measurement. 32:115-130
Non-invasive monitoring of breath ammonia and trimethylamine using Selected-ion-flow-tube mass spectroscopy (SIFT-MS) could provide a real-time alternative to current invasive techniques. Breath ammonia and trimethylamine were monitored by SIFT-MS be
Autor:
Philip F Bagshaw, Andrew R. L. Stevenson, Francis A. Frizelle, Chris Frampton, Randall A. Allardyce, Nicholas A. Rieger, Peter J. Hewett, J. Shona Smith, Michael J. Solomon
Publikováno v:
ANZ Journal of Surgery. 81:125-131
Background: This paper describes the distinctions between major surgical and pharmaceutical trials and questions the application of a common ethical paradigm to guide their conduct and reporting. Methods: Surgical trials differ from other trials in c
Autor:
Chris Frampton, Peter J. Hewett, Philip F Bagshaw, Michael J. Solomon, Nicholas A. Rieger, Andrew R. L. Stevenson, J.S. Smith, Randall A. Allardyce, Frank A. Frizelle
Publikováno v:
British Journal of Surgery. 97:86-91
Background A retrospective analysis of age-related postoperative morbidity in the Australia and New Zealand prospective randomized controlled trial comparing laparoscopic and open resection for right- and left-sided colonic cancer is presented. Metho
Autor:
Philip F Bagshaw, Francis A. Frizelle, Chris Frampton, Randall A. Allardyce, Shona Smith, Michael J. Solomon, Peter J. Hewett, Andrew R. L. Stevenson, Nicholas A. Rieger
Publikováno v:
ANZ Journal of Surgery. 78:840-847
This article describes the initiation and implementation of the multicentre Australia and New Zealand prospective randomized controlled clinical study comparing laparoscopic and conventional open surgical treatments of right-sided and left-sided pote
Autor:
Zoltan H. Endre, K. Ledingham, Katherine T. Moorhead, A. R. Moot, Randall A. Allardyce, Dominic S. Lee, Jennifer M. Scotter, S. Senthilmohan, J.G. Chase
Publikováno v:
Computer Methods and Programs in Biomedicine. 89:226-238
Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) is an analytical technique for real-time quantification of trace gases in air or breath samples. SIFT-MS system thus offers unique potential for early, rapid detection of disease states. Identificati
Autor:
Katherine M. Ledingham, Justin A. Roake, David R. Lewis, Andrew R. Moot, Paul F. Wilson, Randall A. Allardyce, Senti T. Senthilmohan
Publikováno v:
ANZ Journal of Surgery. 77:20-23
Background: There is some evidence that surgical plume may pose a risk to health professionals, but the risks posed by volatile organic compounds have not been thoroughly investigated. Methods: The composition of volatile organic compounds in diather
Publikováno v:
Journal of Microbiological Methods. 65:361-365
To achieve faster bacteremia diagnosis, selected ion flow tube mass spectrometry (SIFT-MS) measured metabolic gases in the headspaces of BacT/ALERT® blood culture bottles. Pseudomonas aeruginosa , Streptococcus pneumoniae , Escherichia coli , Staphy
Publikováno v:
Applied Occupational and Environmental Hygiene. 18:759-763
The new technique of selected ion flow tube-mass spectrometry (SIFT-MS) has been applied to the measurement of Henry's Law constants for the volatile organic chemicals o-xylene and trichloroethylene that both have low solubility in aqueous solvents.
Publikováno v:
Vaccine. 20:2981-2988
The induction of protective immunity against Helicobacter challenge in a murine model was found to correlate with the magnitude of IgG (serum and gastric lavage) responsiveness to intra-nasal (i.n.) immunisation. IgG1-secreting hybridoma backpacks in
Autor:
Geoffrey M. Shaw, Colin G. Freeman, Paul F. Wilson, Daniel B. Milligan, Randall A. Allardyce, Murray J. McEwan
Publikováno v:
Rapid Communications in Mass Spectrometry. 16:427-432
We report measurements of residual vapour levels of xylenes and trimethylbenzenes, present following a floor re-surfacing procedure, using the technique of selected ion flow tube mass spectrometry (SIFT-MS). A subject exposed to controlled amounts of