Zobrazeno 1 - 10
of 17
pro vyhledávání: '"Ralph Neujahr"'
Autor:
Yoshiyuki Kubota, Jaerin Sohn, Sayuri Hatada, Meike Schurr, Jakob Straehle, Anjali Gour, Ralph Neujahr, Takafumi Miki, Shawn Mikula, Yasuo Kawaguchi
Publikováno v:
Nature Communications, Vol 9, Iss 1, Pp 1-15 (2018)
Electron microscopy requires electrically conductive and grounded samples to provide high-resolution, high-contrast images. Here, Kubota et al. describe a suitable carbon nanotube based tape for automated serial section collection and imaging, as in
Externí odkaz:
https://doaj.org/article/a1d66cc212f741208927273556653d6c
Publikováno v:
Frontiers in Neuroanatomy, Vol 12 (2018)
Externí odkaz:
https://doaj.org/article/f9a30fe7db21422bb026e72deb68259e
Autor:
Andreas Oberbach, Nadine Schlichting, Stefan Feder, Stefanie Lehmann, Yvonne Kullnick, Tilo Buschmann, Conny Blumert, Friedemann Horn, Jochen Neuhaus, Ralph Neujahr, Erik Bagaev, Christian Hagl, Maximilian Pichlmaier, Arne Christian Rodloff, Sandra Gräber, Katharina Kirsch, Marcus Sandri, Vivek Kumbhari, Armirhossein Behzadi, Amirali Behzadi, Joao Carlos Correia, Friedrich Wilhelm Mohr, Maik Friedrich
Publikováno v:
PLoS ONE, Vol 12, Iss 4, p e0175569 (2017)
AIMS:In infective endocarditis (IE), a severe inflammatory disease of the endocardium with an unchanged incidence and mortality rate over the past decades, only 1% of the cases have been described as polymicrobial infections based on microbiological
Externí odkaz:
https://doaj.org/article/8b32e98239b140bd93591b315de9b467
Publikováno v:
Volume Microscopy ISBN: 9781071606902
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::febb972c672725323f20745de6d5c8d1
https://doi.org/10.1007/978-1-0716-0691-9_9
https://doi.org/10.1007/978-1-0716-0691-9_9
Autor:
Ralph Neujahr, Yoshiyuki Kubota, Shawn Mikula, Sayuri Hatada, Takafumi Miki, Yasuo Kawaguchi, Jaerin Sohn, Anjali Gour, Jakob Straehle, Meike Schurr
Publikováno v:
Nature Communications, Vol 9, Iss 1, Pp 1-15 (2018)
Nature Communications
Nature Communications
Automated tape-collecting ultramicrotomy in conjunction with scanning electron microscopy (SEM) is a powerful approach for volume electron microscopy and three-dimensional neuronal circuit analysis. Current tapes are limited by section wrinkle format
Publikováno v:
Frontiers in Neuroanatomy
Frontiers in Neuroanatomy, Vol 12 (2018)
Frontiers in Neuroanatomy, Vol 12 (2018)
Microglia are non-neuronal cells of the myeloid lineage that invade and take up long-term residence in the brain during development (Ginhoux et al. 2010) and are increasingly implicated in neuronal maturation, homeostasis, and pathology (Bessis et al
Autor:
Hervé Falet, Thomas P. Stossel, John H. Hartwig, Joseph E. Italiano, Ralph Neujahr, Frederick S. Southwick, Karin M. Hoffmeister
Publikováno v:
Proceedings of the National Academy of Sciences. 99:16782-16787
We investigated the effect of actin filament barbed end uncapping on Arp2/3 complex function both in vivo and in vitro . Arp2/3 complex redistributes rapidly and uniformly to the lamellar edge of activated wild-type platelets and fibroblasts but clus
Publikováno v:
Blood. 100:2113-2122
Arp2/3 complex is believed to induce de novo nucleation of actin filaments at the edge of motile cells downstream of WASp family proteins. In this study, the signaling pathways leading to Arp2/3 complex activation, actin assembly, and shape change we
Publikováno v:
The Journal of Cell Biology
The Arp2/3 complex and filamin A (FLNa) branch actin filaments. To define the role of these actin-binding proteins in cellular actin architecture, we compared the morphology of FLNa-deficient human melanoma (M2) cells and three stable derivatives of
Publikováno v:
Current Biology. 10:501-506
Background: Myosin II, a conventional myosin, is dispensable for mitotic division in Dictyostelium if the cells are attached to a substrate, but is required when the cells are growing in suspension. Only a small fraction of myosin II-null cells fail