Zobrazeno 1 - 10
of 21
pro vyhledávání: '"Rajesh Kumar Panda"'
Publikováno v:
International Journal of Turbo & Jet-Engines.
Film and jet impingement cooling are widely used techniques in gas turbine vane and blade cooling. The present work investigates and compares the flow structure of a film-cooled flat plate with a hybrid cooling scheme. The hybrid cooling scheme combi
Publikováno v:
Journal of Enhanced Heat Transfer.
Publikováno v:
Lecture Notes in Civil Engineering ISBN: 9789811940545
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::5fea758586f663a86758374fb423273e
https://doi.org/10.1007/978-981-19-4055-2_63
https://doi.org/10.1007/978-981-19-4055-2_63
Publikováno v:
Resilience and Sustainable Transportation Systems.
Publikováno v:
IOP Conference Series: Earth and Environmental Science. 796:012046
Many pieces of research have concentrated on traffic speed, time headway, space headway, and so on under non-lane-based heterogeneous traffic streams. In contrast, limited studies have been conducted for analyzing and modeling the vehicular lateral p
Publikováno v:
Journal of Thermophysics and Heat Transfer. 28:647-666
The effect of solid thermal conductivity on conjugate heat transfer from a flat plate with combined impingement and film cooling is studied both experimentally and computationally. One side of the plate is exposed to hot mainstream, whereas the other
Publikováno v:
2016 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES).
Magnetically latched device such as flux shift trip device along with an electronic release are used in circuit breaker so as to protect it against faulty condition. Performance of this device gets effected due to external local magnetic field genera
Publikováno v:
2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES).
Unlike to current transformer, a residual current sensor is highly sensitive to the input leakage current and core material. It senses the leakage current that is produced due to faulty condition in the electrical circuit or unintentional body touch
Publikováno v:
2015 Annual IEEE India Conference (INDICON).
Residual current device being highly sensitive, demands a low coercive and high permeable magnetic material. It should be able to sense all type of signals such as AC with variable frequency, pulsating half and full wave dc, mixed dc and pure dc etc.
Publikováno v:
2015 International Conference on Industrial Instrumentation and Control (ICIC).
With the rapid advancement in smart grid and smart cities across the world there have been great demand for smart meters and protection devices such as digital meter and microprocessor based release and protection unit. These high burden devices dema