BioMedical Engineering OnLine, Vol 10, Iss 1, p 51 (2011)
Abstract Background Guidewire (GW) size and stenosis dimensions are the two major factors affecting the translesional pressure drop. Studying the combined effect of these parameters on the mean pressure drop (Δp) across the stenosis is of high pract
Externí odkaz:
https://doaj.org/article/45bf19d59bce4c73b8632ce6d2dbebae
Autor:
Rajabi-Jaghargh, Ehsan1, Kolli, Kranthi K.1, Back, Lloyd H.2, Banerjee, Rupak K.1 rupak.banerjee@uc.edu
Publikováno v:
BioMedical Engineering OnLine. 2011, Vol. 10 Issue 1, p51-72. 22p.
Autor:
Rajabi Jaghargh, Ehsan
Failure of arteriovenous fistula (AVF) due to formation of stenosis is one of the major causes of morbidity among dialysis patients. Hemodynamic parameters are believed to play a crucial role in the remodeling and functionality of the AVFs. Our centr