Zobrazeno 1 - 10
of 112
pro vyhledávání: '"Rainer Hainberger"'
Autor:
Anja Agneter, Paul Muellner, Quang Nguyen, Dana Seyringer, Elisabet A. Rank, Marko Vlaskovic, Jochen Kraft, Martin Sagmeister, Stefan Nevlacsil, Moritz Eggeling, Alejandro Maese-Novo, Yevhenii Morozov, Nicole Schmitner, Robin A. Kimmel, Ernst Bodenstorfer, Pietro Cipriano, Horst Zimmermann, Rainer A. Leitgeb, Rainer Hainberger, Wolfgang Drexler
Publikováno v:
PhotoniX, Vol 5, Iss 1, Pp 1-21 (2024)
Abstract Photonic integrated circuits (PICs) represent a promising technology for the much-needed medical devices of today. Their primary advantage lies in their ability to integrate multiple functions onto a single chip, thereby reducing the complex
Externí odkaz:
https://doaj.org/article/77e52f28e78244a19c2d731f2c18997e
Publikováno v:
Sensors, Vol 24, Iss 11, p 3678 (2024)
Hydrogels are of great importance for functionalizing sensors and microfluidics, and poly(ethylene glycol) dimethacrylate (PEG-DMA) is often used as a viscosifier for printable hydrogel precursor inks. In this study, 1–10 kDa PEG-DMA based hydrogel
Externí odkaz:
https://doaj.org/article/b357816aec4547a2a1e7dd5188c9ea22
Autor:
Esra Cihan, Eva Melnik, Steffen Kurzhals, Paulina Plata, Giorgio C. Mutinati, Rainer Hainberger, Alfons K.G. Felice, Christopher Schulz, Peter Lieberzeit
Publikováno v:
Chemosensors, Vol 12, Iss 3, p 36 (2024)
Third-generation biosensors use enzymes capable of direct electron transfer (DET) to the sensor surface. They are of interest for continuous glucose monitoring in blood or interstitial fluid, but they are rarely investigated. One reason is the hinder
Externí odkaz:
https://doaj.org/article/d44561c890414695b89bb59dc0066eb5
Autor:
Vanessa Thoeny, Eva Melnik, Malahat Asadi, Pooyan Mehrabi, Thomas Schalkhammer, Walter Pulverer, Thomas Maier, Giorgio C. Mutinati, Peter Lieberzeit, Rainer Hainberger
Publikováno v:
Talanta Open, Vol 6, Iss , Pp 100150- (2022)
For anticancer therapy and disease prognosis in breast cancer, three PIK3CA point-mutations (H1047R, E545K, and E542K) play a significant role. To allow for specific and sensitive detection of these point-mutations with a hybridization-based detectio
Externí odkaz:
https://doaj.org/article/4bee6fc8dd634001a87652157f2ed3d8
Autor:
Elisabet A. Rank, Stefan Nevlacsil, Paul Muellner, Rainer Hainberger, Matthias Salas, Stefan Gloor, Marcus Duelk, Martin Sagmeister, Jochen Kraft, Rainer A. Leitgeb, Wolfgang Drexler
Publikováno v:
Scientific Reports, Vol 11, Iss 1, Pp 1-12 (2021)
Abstract Photonic integrated circuits (PIC) provide promising functionalities to significantly reduce the size and costs of optical coherence tomography (OCT) systems. This paper presents an imaging platform operating at a center wavelength of 830 nm
Externí odkaz:
https://doaj.org/article/6c5a40edb73243fd881c2f9a63ba0c09
Publikováno v:
Biosensors and Bioelectronics: X, Vol 10, Iss , Pp 100136- (2022)
Lateral flow devices (LFDs) allow for low-cost decentralized testing with a short time to result and are therefore an indispensable tool for point-of-care diagnostics. Here, we report on a novel LFD with electrochemical readout for the quantitative d
Externí odkaz:
https://doaj.org/article/61ef48b11ffd475eb84ff1870942e2d6
Autor:
Elisabet A. Rank, Ryan Sentosa, Danielle J. Harper, Matthias Salas, Anna Gaugutz, Dana Seyringer, Stefan Nevlacsil, Alejandro Maese-Novo, Moritz Eggeling, Paul Muellner, Rainer Hainberger, Martin Sagmeister, Jochen Kraft, Rainer A. Leitgeb, Wolfgang Drexler
Publikováno v:
Light: Science & Applications, Vol 10, Iss 1, Pp 1-15 (2021)
Optical coherence tomography: chip promise The goal of an optical coherence tomography (OCT) imaging system that is integrated on a photonic chip has taken a step closer to reality. Elisabet Rank and coworkers from Austria have shown that arrayed wav
Externí odkaz:
https://doaj.org/article/4080f9d7388f433d9123c3e0e2c421d3
Autor:
Martin Sagmeister, Günther Koppitsch, Paul Muellner, Stefan Nevlacsil, Alejandro MaeseNovo, Rainer Hainberger, Dana Seyringer, Jochen Kraft
Publikováno v:
Proceedings, Vol 2, Iss 13, p 1023 (2018)
As a leading provider of sensing solutions ams AG is developing semiconductor sensors in a wide variety of fields. One of the key competences of ams AG lies in optical sensing. To widen the company’s portfolio in this field we have been developing
Externí odkaz:
https://doaj.org/article/e83ab880ed0c46f5b7b81763429e9288
Publikováno v:
Proceedings, Vol 2, Iss 13, p 1026 (2018)
A two-dimensional photonic crystal defect waveguide sensor based on CMOS-compatible silicon-on-insulator technology was designed for operation in aqueous solutions at a wavelength of 1.34 µm, by the use of the 3D Plane Wave Expansion and the Finite
Externí odkaz:
https://doaj.org/article/0b0bacd0b47a49e8b1966c6d277a06bd
Autor:
Eva Melnik, Iris Muschlin, Agnes Wildauer, Mirco Raskovic, Joerg Schotter, Michael Heilmann, Dirk Ide, Michael Borinski, Peter Lieberzeit, Nadezhda Kataeva, Giorgio C. Mutinati, Rudolf Heer, Rainer Hainberger
Publikováno v:
Proceedings, Vol 1, Iss 4, p 619 (2017)
Results are presented regarding the development of recycled paper based impedance biosensors with screen printed interdigitated electrode structures (IDES). The sensors show a response to increasing salt concentrations in the range 30–100 mM NaCl.
Externí odkaz:
https://doaj.org/article/329f3fe70116455686d358aa58ea5856