Zobrazeno 1 - 10
of 460
pro vyhledávání: '"Radial Pulse"'
Autor:
Yi Lyu, Hai-Mei Wu, Hai-Xia Yan, Rui Guo, Yu-Jie Xiong, Rui Chen, Wen-Yue Huang, Jing Hong, Rong Lyu, Yi-Qin Wang, Jin Xu
Publikováno v:
BMC Medical Informatics and Decision Making, Vol 24, Iss 1, Pp 1-21 (2024)
Abstract Background Coronary artery disease (CAD) is a major global cardiovascular health threat and the leading cause of death in many countries. The disease has a significant impact in China, where it has become the leading cause of death. There is
Externí odkaz:
https://doaj.org/article/aa428289c49a4c078a09504e3f0fafdc
Publikováno v:
BMC Complementary Medicine and Therapies, Vol 23, Iss 1, Pp 1-15 (2023)
Abstract Background Patients with Polycystic ovary syndrome (PCOS) experienced endocrine disorders that may present vascular function changes. This study aimed to classify and predict PCOS by radial pulse wave parameters using machine learning (ML) m
Externí odkaz:
https://doaj.org/article/9933234309a949c4b03c0f461230d876
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Micromachines, Vol 13, Iss 10, p 1699 (2022)
Wearable pulse detection devices can be used for daily human healthcare monitoring; however, the relatively poor flexibility and low sensitivity of the pulse detection devices are hindering the scrutiny of pulse information during pulse diagnosis of
Externí odkaz:
https://doaj.org/article/c51c086cc3dd4952b5a42169dc05f860
Publikováno v:
IEEE Access, Vol 7, Pp 182846-182859 (2019)
This study proposes the prototype of a wrist pulse acquisition device with three-dimensional pulse image (3DPI) obtained at the radial artery. The proposed prototype is designed with mechanical and electronic circuit hardware as well as the control a
Externí odkaz:
https://doaj.org/article/13586fea5208477b88c896301a664088
Publikováno v:
Complementary Therapies in Medicine, Vol 56, Iss , Pp 102607- (2021)
Objectives: Suboptimal health status (SHS) is a dynamic state wherein people have not been diagnosed with a disease but tend to develop diseases. People with SHS often experience fatigue and other nonspecific symptoms, which are related to a deviated
Externí odkaz:
https://doaj.org/article/bd3a46d70d444c6d9340e4e6df75c186
Publikováno v:
IEEE Journal of Translational Engineering in Health and Medicine, Vol 6, Pp 1-9 (2018)
Diabetic patients with silent myocardial ischemia (SMI) have elevated rates of morbidity and mortality and need intensive care and monitoring. An early predictor of SMI may lead to early diagnosis and medical treatment to prevent progression and adve
Externí odkaz:
https://doaj.org/article/73cfe64adac3409e912ded0e9b5c1fc0
Publikováno v:
Malaysian Orthopaedic Journal, Vol 13, Iss 3, Pp 66-68 (2019)
The occurrence of axillary artery injury following proximal humerus fracture dislocation in elderly patient with low velocity fall is uncommon. The patient could have diverse clinical presentations in spite of intact peripheral pulses. We report
Externí odkaz:
https://doaj.org/article/d3f23fac3e2447e1927534d9869be0d4
Publikováno v:
Sensors, Vol 21, Iss 20, p 6837 (2021)
The primary goal of this study is to develop a mathematical model that can establish a transfer function relationship between the “external” pulse pressures measured by a tonometer and the “internal” pulse pressure in the artery. The purpose
Externí odkaz:
https://doaj.org/article/4336d55c2c55481785316adf9a981f14