Zobrazeno 1 - 10
of 62
pro vyhledávání: '"R.L. Shepard"'
Autor:
J.M. Weiss, R.L. Shepard
Publikováno v:
IECEC 96. Proceedings of the 31st Intersociety Energy Conversion Engineering Conference.
Control of the nuclear power source for the SP-100 electric power supply required a thermometer that would be 1% accurate at temperatures to 1100/spl deg/C (1300 K) with no drift and unattended operation for more than 7 years in moderate radiation en
Autor:
R.J. Huckins, R.L. Shepard
Publikováno v:
Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.
An advanced, general-purpose architecture has been employed in the design and implementation of a next-generation spectroscopy acquisition and analysis platform. The major design goals for the architecture were portability across multiple 'high-end'
Autor:
R.L. Shepard, A. Mohamed
As part of an effort to improve the teaching of science in a four-State region (Alabama, Mississippi, Louisiana, and Texas), the Science and Engineering Alliance (SEA) initiated a series of teacher enhancement workshops in science. The workshops focu
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::0d24362a2bd99c7929009542dca5b473
https://doi.org/10.2172/587719
https://doi.org/10.2172/587719
A program is recommended for planning the maintenance of DOE nuclear facilities that will help safety and enhance availability throughout a facility`s life cycle. While investigating the requirements for maintenance activities, a major difference was
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::0dbb4cea26811ab809b1c9096ae7f362
https://doi.org/10.2172/10191448
https://doi.org/10.2172/10191448
Autor:
R.L. Shepard, L.H. Thacker
Advanced distributed control systems for electric power plants will require more accurate and reliable pressure gauges than those now installed. Future developments in power plant control systems are expected to use digital/optical networks rather th
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::12fbdf25cf27c37fca3eebb9bc7a133a
https://doi.org/10.2172/10190000
https://doi.org/10.2172/10190000
Publikováno v:
IEEE Transactions on Industrial Electronics and Control Instrumentation. :137-144
An equivalent circuit and computer solution were formulated for describing the output of a metal-sheathed bifilar thermocouple degraded by insulator shunting at high temperatures. This steady-state equivalent circuit model can be used for prediction
Autor:
R.L. Shepard, L.F. Miller
Methods for obtaining unbiased parameter estimates from data obtained by in situ tests of temperature detectors are evaluated. A computer program that calculates unbiased estimates of parameters that define a dynamic model of the temperature detector
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::0ac5683b7166537f1d621013ab58f46e
https://doi.org/10.2172/5813288
https://doi.org/10.2172/5813288
Autor:
R.M. Carroll, R.L. Shepard
A loop-current step-response (LCSR) method was developed to measure, in situ, the transient response of temperature sensors, such as thermocouples and resistance thermometers. In this method, a sensor is heated with an electric current, and the time
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::5f6f05fbc57711edc9ab3bda3a5fcd15
https://doi.org/10.2172/7221079
https://doi.org/10.2172/7221079
Autor:
R.L. Shepard, R.M. Carroll
Laboratory tests conducted on one resistance thermometer and thermowell removed from TMI-2 showed that neither its calibration nor its time response was adversely affected by the accident or post-accident conditions to which it had been exposed. No N
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::f3c6280995c632b8f4f1dc3b13932b02
https://doi.org/10.2172/5063009
https://doi.org/10.2172/5063009