Zobrazeno 1 - 10
of 143
pro vyhledávání: '"R.J. Minns"'
Publikováno v:
Proceeding of Flexible Automation and Integrated Manufacturing 1999.
Publikováno v:
Medical Engineering & Physics. 25:523-526
The use of a rapid prototyping method was utilised to produce a pre-operative solid model of the proximal tibia in a patient with a massive defect of the medial tibial plateau. The solid model was reconstructed from aligned sequential CT images of th
Publikováno v:
The Knee. 6:171-174
The computer simulation shows the effect, if any, on the ageing/disease process on the articular cartilage during the forces encountered on a fully loaded knee bend. A finite element model of the patella was produced in which all four of the material
Publikováno v:
Foot and Ankle Surgery. 5:245-250
Summary A porous pad of carbon fibre made into implants of 3 mm thickness was used in a study of the surgical management for the painful condition of hallux rigidus. The convex surface of the proximal phalanx was excavated to produce an undermined tr
Publikováno v:
The Knee. 4:185-191
The preliminary results of the Minns meniscal bearing total knee replacementare presented with an average follow-up of 62.5 months (range 38–78 months). A total of 90 cemented meniscal bearing total replacements of this design were performed on 67
Autor:
Gordon Blunn, Lars Lidgren, E. Engelbrecht, R.J. Minns, Peter S. Walker, Atul B. Joshi, P. Lilley, Leif Ryd
Publikováno v:
The Journal of Arthroplasty. 12:281-290
The plastic components of 280 retrieved unicondylar and total knee arthroplasties were studied. Wear was visually scored using a relative ranked data method. Although wear on the components was highly variable, several conclusions could be drawn rega
Publikováno v:
The Knee. 1:57-64
Sixty-one polyethylene bearings from an early design of the ‘Minns’ meniscal knee prosthesis have been retrieved from 32 patients after an average of 55 months in situ . The knee had traumatically dislocated in 22 cases, five polyethylene compone
Publikováno v:
Biomaterials. 11:13-16
Eighteen New Zealand white rabbits underwent prosthetic replacement of the meniscus which was attached to the intercondylar area of the tibia through a predrilled hole and around the internal surface of the capsule by sutures, in one knee, and menisc
The successful repair of articular cartilage must rely on the restoration of the full thickness of the layer with full structural integration laterally with the existing material on the joint surface. The knee is the most commonly affected joint for
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::6a4f7e5fb9630d3e8bbcbe5d1dffd6bd
https://doi.org/10.1533/9781845694104.6.335
https://doi.org/10.1533/9781845694104.6.335
Autor:
R.J. Minns
Publikováno v:
The Knee. 12(3)
Gait analysis has been used as an investigative tool for locomotion disorders since the early 20th century when it was done using time-lapsed photography. Since the advent of video and advances in strain gauge technology and fast data-handling device