Infrared Physics & Technology. 37:335-341
A critical review of the methods to measure the optical constants n and k of metal shows a severe fall in sensitivity in the infrared range. A new sensitive method which consists in obtaining ( n,k ) by fitting the reflectivity R p at near grazing in
Publikováno v:
Measurement Science and Technology. 7:52-57
Avery's and Simon's reflection methods for determining the optical constants n and k were analysed in order to determine the corresponding angles of incidence of greatest sensitivity. For estimating the method sensitivity we used the point sensitivit
Publikováno v:
Applied optics. 35(1)
The Darcie–Whalen reflection method is ambiguous and has a chart area of 72%, which is less sensitive than method H—Owen's classification—which is unambiguous and has a chart area of 100%.
Autor:
R. Tumbar
Publikováno v:
2008 Conference on Lasers and Electro-Optics.
We coupled a compact and robust phase-shifting and shearing interferometer (sampling field sensor) to the imaging port of a standard, infinity corrected, transmission microscope to obtain phase, amplitude and polarization images of unstained biologic
Autor:
Dan Apostol, Alexandru Ioan Ciura, Petre-Catalin Logofatu, Victor Damian, R. Tumbar, M. Stoica
Publikováno v:
SPIE Proceedings.
Complex refractive index determination (refractometry) of metals can be made successfully with methods using reflectivity measurements. In this paper a brief classification of reflectivity methods with subsequent comments about their sensitivity is m
Publikováno v:
SPIE Proceedings.
The measurement of large angles is still an actual problem in metrology. Interferometric methods based on Michelson interferometer have high sensitivities, precision and accuracy but the angular range is limited. Two methods are presented: hollow roo
Autor:
R. Tumbar, Dan Apostol, Victor Damian, Petre-Catalin Logofatu, Adrian Dobroiu, Constantin Blanaru
Publikováno v:
SPIE Proceedings.
An interferometric set-up able to measure angles as large as +180 degree(s) is presented. The principle of the method is to measure a linear displacement (translation) produced by a crank-gear mechanism which converts the angular movement of a rotati
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.