Zobrazeno 1 - 10
of 113
pro vyhledávání: '"R. Poledna"'
Autor:
C.J. da Silva, Mam Araujo, P.A.L. da Cruz, C.F. Arcanjo, Ricardo Tadeu Lopes, A. L. Ferreira Filho, José Ubiratan Delgado, R.W.R.V. Da Silva, R. Poledna
Publikováno v:
Applied Radiation and Isotopes. 134:340-350
The sum-peak method, an absolute measurement technique that uses coincidence counting and γ-ray spectrometry, was applied to activity standardization of 152Eu sources. The decay branch used was that of 152Sm, as it is almost entirely electron captur
Autor:
A. da S. Laranjeira, R. Poledna, Akira Iwahara, Paulo Alberto Lima da Cruz, C.J. da Silva, R.L. da Silva, M.T.F. de Araújo, A.R.L. dos Santos, J. dos S. Loureiro, R. dos S. Gomes
Publikováno v:
Applied Radiation and Isotopes. 134:316-320
From a commercial supplier a solution containing 134Cs has been standardized at National Laboratory for Ionizing Radiation Metrology (LNMRI) for the first time using three Liquid scintillation based measurement. These measurement methods are 4πβ-γ
Standardization of 106 Ru/Rh by live-timed anticoincidence counting and gamma emission determination
Publikováno v:
Applied Radiation and Isotopes. 122:37-40
The absolute activity standardization measurement system of radionuclide by live-timed anticoincidence counting was implemented at LNMRI in 2008 to reduce the effects of some correction factors on the determination of activity with coincidence counti
Autor:
Akira Iwahara, R. Poledna, Carlos José da Silva, Estela Maria de Oliveira, Regio dos Santos Gomes, José Ubiratan Delgado, Paulo Alberto Lima da Cruz, Ricardo Tadeu Lopes
Publikováno v:
Brazilian Journal of Radiation Sciences. 7
A 68(Ge+Ga) commercial solution has been standardized in LNMRI in Brazil, by sum-peak method, in which a 3”x3” NaI(Tl) gamma-ray detector is positioned at the top of a well-type 5”x5” NaI(Tl) gamma-ray detector, resulting in a set up approxim
Autor:
L.V. de Sá, R. Poledna, José Ubiratan Delgado, R.L. da Silva, A.E. de Oliveira, Akira Iwahara, C.J. da Silva, Rafael Figueiredo Pohlmann Simões, P.A.L. da Cruz
Publikováno v:
Applied Radiation and Isotopes. 170:109559
From a commercial supplier, three independent lots of an aqueous solution containing 223Ra in equilibrium with its deteriorating progeny were considered for standardization, by using live-time anticoincidence counting (LTAC) in the Laboratorio Nacion
Autor:
Akira Iwahara, R. Poledna, M.C.M. de Almeida, José Ubiratan Delgado, Antonio Eduardo de Oliveira, Luiz Tauhata, M. T. F. Araújo, C.J. da Silva, Ronaldo Lins da Silva, Ricardo Tadeu Lopes
Publikováno v:
Applied Radiation and Isotopes. 109:389-392
(123)I is widely used for radiodiagnostic procedures. It is produced by reaction of (124)Xe (p,2n) (123)Cs →(123)Xe →(123)I in cyclotrons. (121)Te and (125)I appear in a photon energy spectrum as impurities. An activity of (121)Te was calibrated
Autor:
R F P, Simões, C J, da Silva, R L, da Silva, L V, de Sá, R, Poledna, A E, de Oliveira, A, Iwahara, P A L, da Cruz, J U, Delgado
Publikováno v:
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 170
From a commercial supplier, three independent lots of an aqueous solution containing
Autor:
Carlos José da Silva, R. Poledna, Paulo Alberto Lima da Cruz, Lídia Vasconcellos de Sá, Rafael Figueiredo Pohlmann Simões, Ronaldo Lins da Silva
Publikováno v:
Brazilian Journal of Radiation Sciences. 6
The Radium-223 ( 223 Ra) has being used as a medicine for localized treatment of patients with osteoblastic metastasis originated by prostate cancer resistant of castration or hormone refractory. For a better treatment with this radionuclide, clinica
Autor:
E V de Veras, R. Poledna, M.C.M. de Almeida, A.S. Laranjeira, M.T.F. de Araújo, G.R. dos Santos, R.L. da Silva, A.M.S. Braghirolli, Ricardo Tadeu Lopes, Juliana Delgado
Publikováno v:
Applied Radiation and Isotopes. 109:261-263
(124)I is a radionuclide used in the diagnosis of tumors. The National Health Agency requires identification and activity measurement of impurities. Using gamma spectrometry with an efficiency calibrated high-purity germanium detector, impurities (12
Autor:
Miriam Tainá Ferreira de Araújo, R. Poledna, Anderson Leiras, Eduardo Bonfim De Paula, José Ubiratan Delgado
Publikováno v:
Brazilian Journal of Radiation Sciences. 5
LNMRI has sought to develop a methodology for the identification and accurate detection of impurities emitting gamma radiation at the metrological level, aiming to meet the recommendations not only of the international pharmacopoeia, but also of CNEN