Zobrazeno 1 - 10
of 22
pro vyhledávání: '"R. Lenarduzzi"'
Autor:
Milton Nance Ericson, Mark Wilson, R. Lenarduzzi, Weijian Xu, C.L. Britton, M.S. Hileman, Miljko Bobrek, M.S. Emery, Michael R. Moore, Gerard L. Coté, Justin S. Baba
Publikováno v:
Minimally invasive therapyallied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy. 13(2)
A limited number of techniques are employed in clinical medicine for regional tissue perfusion assessment. These methods are marginally effective and are not well suited for implantation due to the inability to miniaturize the associated technologies
Autor:
Timothy E. Valentine, T. Uckan, James Allen Mullens, Jose March-Leuba, J.A. McEvers, K.N. Castleberry, R. Lenarduzzi, John T. Mihalczo, John Mattingly, Michael J. Paulus
Publikováno v:
1997 IEEE Nuclear Science Symposium Conference Record.
A computer controlled detector/electronics module has been designed and constructed for the Oak Ridge National Laboratory fissile mass flow (FMF) monitor. The FMF monitor employs a host computer, a modulated neutron source (Cf-252) and four of the ga
Autor:
Brian Damiano, S.W. Kercel, R. Crutcher, P.R. Bingham, T.F. Gee, Michael R. Moore, J. E. Hardy, K. Weaver, R. Lenarduzzi, R.W. Tucker, R.H. Vandervaart, R.V. Kolarik, M. Hileman, Roger A. Kisner, M.S. Emery
Researchers at the Timken Company conceived a project to develop an on-line instrument for wall thickness measurement of steel seamless mechanical tubing based on laser ultrasonic technology. The instrument, which has been installed and tested at a p
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::7d67e6d279f6caacfd7882c4fe7c8b68
https://doi.org/10.2172/940387
https://doi.org/10.2172/940387
Autor:
P.A. Taylor, T.A. Dillow, K.K. Anderson, R.D. Hunt, M.W. Getting, D.A. Bostick, A.J. Mattus, T.D. Welch, W.R. Wilmarth, R. Lenarduzzi
Crystalline silicotitanate (CST) sorbent is one of several technologies being evaluated by the Savannah River Site (SRS) for removing cesium from high-level tank-waste supernatant. As currently envisioned, three large 5-ft-diam, 20-ft-high ion-exchan
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::03ea04017058e23b888d645820a23d50
https://doi.org/10.2172/754361
https://doi.org/10.2172/754361
Autor:
R. Lenarduzzi, R. N. Nodine
The purpose of this document is to describe the use and operation of the sensor concentrator in the Continuous Automated Vault Inventory System (CAVIS). The CAVIS electronically verifies the presence of items of stored special nuclear material (SNM).
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::f01252d6b85cb644e65ffef11d770d08
https://doi.org/10.2172/654210
https://doi.org/10.2172/654210
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Conference
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Conference
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.