Zobrazeno 1 - 10
of 49
pro vyhledávání: '"R. Fasching"'
Autor:
A. Lechner, M. Schrödl, R. Weiß, E. Brenner, P. Seifter, W. Kosta, G. Raimann, F. Furtner, D. Kirchner, H. Bühler, B. Nemsic, W. Jerono, G. Horak, R. Messaros, F. Seifert, P. Fey, A. Goßlau, A. Gottwald, W. Gáspár-Ruppert, P. Kreuzgruber, A. L. Scholtz, W. Smutny, P. Koschnick, W. Schulz, R. Schwarze, Peter W. Fröhling, Robert Casari, E. Fugger, P. Spinadel, J. Niwinski, L. Prager, E. Schauer, G. Rigler, K. Moshammer, H. Arnold, W. Pribyl, R. Röhrer, W. A. Halang, K. Barbier, F. Schiestl, C. Blind, H. Kamper, A. Krenn, H. Fleischmann, R. Schlager, L. Sturm, J. Retti, S. Rohringer, H. Schreiner, G. Fleischanderl, W. Höllinger, R. Fasching, G. Stonawski, H. Huber, J. Jaeger, H. Stadlbauer, R. Weissgärber, W. Reczek, H. Terletzki, Titu I. Bajenescu, T. Grechenig, Ch. Heinze, P. Purgathofer, J. Kohl, E. Schoitsch, G. Stöckler, F. Immitzer, W. Kasatschinskij, R. Eier, R. Neumann, F. Buschbeck, E. Riedl-Bratengeyer, D. Hornbachner, G. Güttler, C. Schmitzer, W. Klösch, A. Nedelik, E. Schöberl, W. Tritremmel, E. Schmidt, M. Gröschl, E. Benes, H. Siegmund, G. Thorn, G. F. Nowa
Die Informationstagung'Mikroelektronik'findet im Rahmen der ie (Internationale Fachmesse für industrielle Elektronik) seit dem Jahr 1975 im Abstand von zwei Jahren statt. Die Einzelbeiträge der Tagung 1989 werden in dem vorliegenden Band in übersi
Publikováno v:
Measurement. 33:109-119
Miniaturized flow sensors based on thin film germanium thermistors were developed offering high flow sensitivities and short response times. The thermistors are placed on a silicon nitride diaphragm carried by a silicon frame. Using the controlled ov
Autor:
Franz Kohl, R. Fasching, Franz Keplinger, G. Jobst, R. Chabicovsky, Gerald Urban, G. Hanreich
Publikováno v:
Sensors and Actuators B: Chemical. 78:291-297
In this paper, we report on a thin film sensor for the detection of carbon dioxide dissolved in liquids with the attention focused on its use for clinical blood gas analysis. Carbon dioxide from the analyte penetrates into a hydrogel electrolyte thro
Surface modification of platinum thin film electrodes towards a defined roughness and microsporosity
Autor:
Gerhard Jobst, E. Aschauer, G. K. Nicolussi, R. Fasching, Gerald Urban, W. Husinsky, G. Friedbacher, M. Grasserbauer, M. Varahram
Publikováno v:
Journal of Electroanalytical Chemistry. 426:157-165
The roughness and microsporosity of platinum thin-film electrodes, which act as transducers in electrochemical biosensors, have been varied by evaporating titanium or aluminum as top layers and subsequent annealing and etching of these metal films. T
Publikováno v:
Journal of Electroanalytical Chemistry. 381:143-150
The surface of platinum thin-film electrodes, which are used for electrochemical biosensors, was investigated by cyclic voltammetry and laser secondary neutral mass spectroscopy (LSNMS). The platinum electrodes act as transducers and amperometrically
Autor:
Franz Kohl, R. Fasching, O. Tilado, Franz Keplinger, E. Aschauer, Gerald Urban, Gerhard Jobst
Publikováno v:
Biosensors and Bioelectronics. 7:733-739
An electrochemical glucose sensor has been integrated, together with a pH sensor, on a flexible polyimide substrate for in vivo applications. The glucose sensor is based on the measurement of H2O2 produced by the membrane-entrapped enzyme glucose oxi
Publikováno v:
Multisensorikpraxis ISBN: 9783642643651
In vielen Bereichen der Medizin, unter anderem in der Diabetologie und in der Intensivmedizin, wachst die Notwendigkeit, wahtige metabolische Parameter online messen zu konnen. Nur mit Monitoring und bettseitiger Analyse wahrend Operationen und in de
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::14d4b0e8806ff65c48c86c077bbff1be
https://doi.org/10.1007/978-3-642-60348-8_11
https://doi.org/10.1007/978-3-642-60348-8_11
This chapter elaborates the ex vivo and in vivo evaluation of biosensors. The sensor device consists of a flexible polymer, carrier of 0.1 mm thickness with length of 60 mm and width of 0.7 mm. A Pt counter electrode, two Pt working electrode and a A
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::8ceaacf5560dad6c51c0e23672f9d8e9
https://doi.org/10.1016/b978-1-85617-242-4.50083-5
https://doi.org/10.1016/b978-1-85617-242-4.50083-5
This chapter discusses numerical simulation of membranized enzyme sensors. A lot of work is already done on the simulation of the steady state and transient performance of enzyme based sensors. However, little attention is paid to specific effects th
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::db6ef0a4813fb1f938d81884bf2186db
https://doi.org/10.1016/b978-1-85617-242-4.50196-8
https://doi.org/10.1016/b978-1-85617-242-4.50196-8