Zobrazeno 1 - 10
of 22
pro vyhledávání: '"R. D. Medina"'
Autor:
L. Di Feo, Wilmer J. Cuellar, M. G. Celli, R. D. Medina, Andrea Alejandra Zanini, V. C. Conci, A. V. Luque
Publikováno v:
Plant Pathology. 67:1814-1820
Cassava common mosaic disease (CCMD) has been reported in all regions where cassava is grown in the Americas and the causal agent, Cassava common mosaic virus (CsCMV), has been identified as a mechanically transmitted potexvirus (Alphaflexiviridae).
Publikováno v:
Electric Power Systems Research. 151:1-11
This paper presents a novel method for estimating the degradation of solid insulation in power transformers, considering thermal ageing and paper moisture dynamics. Current ageing models are based on both, experimental evidence and theoretical develo
Publikováno v:
CCECE
This document presents an innovative tool for assessing the consequence of the final failure a power transformer, this metric considers aspects as: power quality, overload of other equipment, safety, reliability of the system and the environmental &
Publikováno v:
Studies in Systems, Decision and Control ISBN: 9783319744117
This chapter presents a review of a proposed model for smart grid implementation on the Galapagos Islands. Unique characteristics of the archipelago such as difficult to transport consumables and fuel from the continent, the stress on public services
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::a9846bd5245249e30946c6ac0a1187d2
https://doi.org/10.1007/978-3-319-74412-4_14
https://doi.org/10.1007/978-3-319-74412-4_14
Publikováno v:
IEEE Latin America Transactions. 13:3287-3293
In this paper a comparison between two methods for the calculation of the hot spot temperature of a power transformer is presented. The first method is proposed by C57.91 IEEE Standard which is based on daily averages and exponential equations; on th
Publikováno v:
2017 CHILEAN Conference on Electrical, Electronics Engineering, Information and Communication Technologies (CHILECON).
This paper presents a method for assess the risk index in a power transformers park, risk index is a metric that allows park administrator to ensure an optimal physical asset management, allocating properly financial and human resources in operation
Publikováno v:
2017 CHILEAN Conference on Electrical, Electronics Engineering, Information and Communication Technologies (CHILECON).
This paper presents a method for assess the risk index in a power transformers park, risk index is a metric that allows park administrator to ensure an optimal physical asset management, allocating properly financial and human resources in operation
Publikováno v:
2017 IEEE XXIV International Conference on Electronics, Electrical Engineering and Computing (INTERCON).
This paper analyses the influence of common test in power transformers health index assessing. To achieve this objective a test based sensibility analysis is proposed. To show results, a study case is proposed, using a set of real scenarios analyzes
Publikováno v:
2017 International Caribbean Conference on Devices, Circuits and Systems (ICCDCS).
This paper presents a sensitivity analysis of a health index of power transformers tool, in order to identify the importance of each input to determine most important and those that can be dismissed to simplify the calculation process without signifi