Zobrazeno 1 - 10
of 17
pro vyhledávání: '"R. Bulder"'
Publikováno v:
European Journal of Vascular and Endovascular Surgery. 65:e84-e85
Autor:
Rien A.J.M. Huybregts, R C E Paulus, H Te Velthuis, Michiel Wagemakers, W. van Oeveren, Charles R.H. Wildevuur, W. R. Wildevuur, R de Vroege, Leon Eijsman, Eisso R. Bulder
Publikováno v:
Asaio Journal, 47(1), 37-44
The new generation of oxygenators have improved blood flow pathways that enable reduction in priming volume and, thus, hemodilution during cardiopulmonary bypass (CPB). We evaluated three oxygenators and two sizes of venous reservoirs in relation to
Autor:
J.P.P.M. de Vries, P. M. J. M. De Vries, E. R. Bulder, W. O. Schreuder, B. J. M. Van Der Meer, L. Eysman
Publikováno v:
Acta Anaesthesiologica Scandinavica. 41:708-712
To study the accuracy of cardiac output measurement by means of Electrical Impedance Cardiography (EIC) in post-cardiac surgery patients.In a prospective study, we compared cardiac output measurements by means of thermodilution (COTD) with impedance
Autor:
M. A. J. M. Huybregts, H. H. Woltjer, A. M. Sousman, E. R. Bulder, W. O. Schreuder, P. M. J. M. De Vries, B. J. M. van der Meer
Publikováno v:
Intensive Care Medicine. 22:1120-1124
Objective : Electrical impedance cardiography (EIC) has been suggested as a non-invasive method to measure cardiac output. In several studies it proved to be a reliable method, although there were some restrictions. In 1966 Kubicek et al. developed a
Autor:
Rien A.J.M. Huybregts, Reginald Paulus, Hans I. van der Spoel, P.Dick Bezemer, Henk te Velthuis, Piet G.M. Jansen, Charles R.H. Wildevuur, Ed H. Slaats, Eisso R. Bulder, Leon Eijsman
Publikováno v:
Jansen, P G M, te Velthuis, H, Huybregts, R A J M, Paulus, R, Bulder, E R, van der Spoel, H I, Bezemer, P D, Slaats, E H, Eijsman, L & Wildevuur, C R H 1995, ' Reduced complement activation and improved postoperative performance after cardiopulmonary bypass with heparin-coated circuits ', The Journal of Thoracic and Cardiovascular Surgery, vol. 110, no. 3, pp. 829-834 . https://doi.org/10.1016/S0022-5223(95)70117-6
The Journal of Thoracic and Cardiovascular Surgery, 110(3), 829-834. Mosby Inc.
The Journal of Thoracic and Cardiovascular Surgery, 110(3), 829-834. Mosby Inc.
A randomized controlled trial that involved 30 patients undergoing elective coronary artery bypass grafting was done to determine the effect of heparin-coated circuits and full heparinization on complement activation, neutrophil-mediated inflammatory
Autor:
Leon Eijsman, P. G. M. Jansen, S. J.H. Van Deventer, A. Sturk, Eisso R. Bulder, H. M. Oudemans-van Straaten, H. te velthuis, Ch. R. H. Wildevuur
Publikováno v:
European Journal of Cardio-thoracic Surgery, 8(3), 125-129. Elsevier
Jansen, P G M, Te Velthuis, H, Oudemans-Van Straaten, H M, Bulder, E R, Van Deventer, S J H, Sturk, A, Eijsman, L & Wildevuur, C R H 1994, ' Perfusion-related factors of endotoxin release during cardiopulmonarybypass ', European Journal of Cardio-thoracic Surgery, vol. 8, no. 3, pp. 125-129 . https://doi.org/10.1016/1010-7940(94)90167-8
Jansen, P G M, Te Velthuis, H, Oudemans-Van Straaten, H M, Bulder, E R, Van Deventer, S J H, Sturk, A, Eijsman, L & Wildevuur, C R H 1994, ' Perfusion-related factors of endotoxin release during cardiopulmonarybypass ', European Journal of Cardio-thoracic Surgery, vol. 8, no. 3, pp. 125-129 . https://doi.org/10.1016/1010-7940(94)90167-8
To investigate whether the release of endotoxin during cardiopulmonarybypass (CPB) is determined by perfusion-related factors, endotoxinconcentrations were determined before, during, and after CPB in 21 malepatients (age range 45-75 years) undergoing
Publikováno v:
Perfusion. 17(1)
Cardiac surgery on Jehovah’s Witnesses is a great challenge for the cardiothoracic surgery team and especially for the perfusionist. To reduce the risk of surgery in these patients, a very small extracorporeal circuit was designed to decrease the a
Autor:
B J, van der Meer, H H, Woltjer, A M, Sousman, W O, Schreuder, E R, Bulder, M A, Huybregts, P M, de Vries
Publikováno v:
Intensive care medicine. 22(10)
Electrical impedance cardiography (EIC) has been suggested as a non-invasive method to measure cardiac output. In several studies it proved to be a reliable method, although there were some restrictions. In 1966 Kubicek et al. developed an impedance
Autor:
Eisso R. Bulder, H. te Velthuis, Leon Eijsman, P. G. M. Jansen, M. A. J. M. Huybregts, H. I. Van Der Spoel, A. Sturk, Ch. R. H. Wildevuur, W. R. Wildevuur
Publikováno v:
Jansen, P G M, Te Velthuis, H, Wildevuur, W R, Huybregts, M A J M, Bulder, E R, Van Der Spoel, H I, Sturk, A, Eijsman, L & Wlldevuur, C R H 1996, ' Cardiopulmonary bypass with modified fluid gelatin and heparin-coated circuits ', British Journal of Anaesthesia, vol. 76, no. 1, pp. 13-19 . https://doi.org/10.1093/bja/76.1.13
British Journal of Anaesthesia, 76(1), 13-19. Oxford University Press
British Journal of Anaesthesia, 76(1), 13-19. Oxford University Press
We have assessed the efficacy of cardiopulmonary bypass (CPB) using normal colloid oncotic pressure (COP) in a randomized, controlled study of 20 patients undergoing elective coronary artery surgery using heparin-coated circuits. For CPB, we used eit
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::424b8b4f4c41fd5a6cc5c4d2ed327552
https://research.vumc.nl/en/publications/0f7a4862-1be2-44a3-a796-0d7535432c73
https://research.vumc.nl/en/publications/0f7a4862-1be2-44a3-a796-0d7535432c73
Autor:
Reggie Paulus, Marc R.M. Scheltinga, Piet G.M. Jansen, Charles R.H. Wildevuur, Leon Eijsman, Henk te Velthuis, Eisso R. Bulder
Publikováno v:
The Annals of thoracic surgery. 60(3)
Background. A hyperdynamic response to cardiopulmonary bypass is characteristically observed in the postoperative course. To determine the effect of prime volume on the hemodynamic response, a database study was performed on patients who underwent el