Zobrazeno 1 - 4
of 4
pro vyhledávání: '"R V, Matthews"'
Autor:
Y, Kobayashi, Y, Honda, G L, Christie, P S, Teirstein, S R, Bailey, C L, Brown, R V, Matthews, A C, De Franco, R S, Schwartz, S, Goldberg, J J, Popma, P G, Yock, P J, Fitzgerald
Publikováno v:
Journal of the American College of Cardiology. 37(5)
We sought to investigate the in vivo mechanical properties of a new self-expanding coronary stent (RADIUS) and, particularly, the subsequent vessel response over time.Preclinical studies have suggested that self-expanding stents may produce less vess
Publikováno v:
Catheterization and cardiovascular diagnosis. 39(3)
Extraction atherectomy utilizes suction aspiration as an attempt to limit distal emboli during atherectomy. We sought to test the hypothesis that extraction atherectomy produces less distal embolization than balloon angioplasty when treating saphenou
Publikováno v:
Catheterization and cardiovascular diagnosis. 38(3)
Directional coronary atherectomy was successfully performed in the mid-left anterior descending artery at the site of failed balloon angioplasty. We presumed that intracoronary thrombus had resulted in acute vessel closure following balloon angioplas
Publikováno v:
Journal of electrocardiology.
Esophageal pill electrode pacing, treadmill exercise and coronary angiography were performed in 23 patients with chest pain. Atrial pacing produced fewer false positive studies resulting in higher specificity compared to treadmill exercise. Some poss