Zobrazeno 1 - 10
of 45
pro vyhledávání: '"R L, Eisner"'
Publikováno v:
IEEE Nuclear Science Symposuim & Medical Imaging Conference.
In PET/CT studies, artifacts can occur in CT/AC scans when parameters are adjusted to reduce CT radiation exposure to very low levels, and these can in turn cause PET errors. Scanning at 80 kVp instead of 120 or 130 kVp can result in attenuation corr
Publikováno v:
Lecture Notes in Computer Science ISBN: 3540542469
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::e044236e14f07aebbb9417b736ce42ad
https://doi.org/10.1007/bfb0033753
https://doi.org/10.1007/bfb0033753
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 37(11)
We estimated that in 75%-90% of PET 82Rb patients the left lung appeared to wrap around the anterior aspect of the left ventricle. We used clinical PET 82Rb myocardial perfusion studies as the input to a SPECT computer simulation model to determine i
Publikováno v:
American journal of cardiac imaging. 10(1)
Diagnosis and assessment of coronary artery disease (CAD) is especially difficult in women. The history of chest discomfort and various noninvasive tests each have particular problems, which indicate the need to consider more accurate tests such as c
Publikováno v:
Heart disease and stroke : a journal for primary care physicians. 3(6)
Autor:
R L, Eisner, L S, Schmarkey, S E, Martin, D, Carey, M A, Worthy, T H, Chu, S F, Horowitz, R E, Patterson
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 35(4)
Technetium-99m-sestamibi images reflect tracer distribution at the time of injection. This "stay put" indicator allowed us to separate the effects of segmental left ventricular dysfunction per se versus myocardial blood flow on SPECT "perfusion" imag
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 34(6)
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 34(2)
By computer simulation, we have previously hypothesized, independent of the isotope imaged, that differences in view-to-view resolution and attenuation patterns predictably cause count density distortions in SPECT images. We tested the simulation pre
Autor:
R L, Eisner
Publikováno v:
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 33(8)
Autor:
R E, Patterson, R L, Eisner
Publikováno v:
Journal of the Medical Association of Georgia. 81(2)