Zobrazeno 1 - 10
of 28
pro vyhledávání: '"R D Beckenbaugh"'
Publikováno v:
Aktuelle Rheumatologie. 31:329-339
Autor:
R. D. Beckenbaugh
Publikováno v:
Der Orthop�de. 32:794-797
Auf der Suche nach alternativen Materialien fur die Endoprothetik an den Handen ist man in den 1970er Jahren auf Pyrocarbon gestosen. Pyrocarbon hat im Einsatz bei der Herzklappenprothetik eine hohe Biokompatibilitat und sehr gute Abriebeigenschaften
Autor:
R D, Beckenbaugh, A D, Steffee
Publikováno v:
Orthopedics. 4(3)
A prosthetic device for the metacarpophalangeal joint of the thumb and the preliminary clinical results are described. The prosthesis is a hinged metal-and-polyethylene device that is cemented into the shaft of the metacarpal and proximal phalanx. Fo
Autor:
H C, Fayaz, R D, Beckenbaugh, K N, An, J J, Klawitter, J, Jerosch, S, Rehart, Hangama C, Fayaz
Publikováno v:
Zeitschrift fur Orthopadie und Unfallchirurgie. 145(2)
Prosthetic replacement in the hand must address such unique challenges as preservation of the collateral ligaments, tendon balancing,and Stability. Surface replacement arthroplasty can be an alternative to other current implants. The purpose of this
Autor:
R D, Beckenbaugh
Publikováno v:
Der Orthopade. 32(9)
As early as the 1970s, pyrocarbon became a point of focus in the search for materials for alternative finger replacement. This type of material had already proven its biocompatibility and excellent wear behaviour in its use for artificial heart valve
Publikováno v:
Clinical orthopaedics and related research. (253)
In four cases, proximal radioulnar synostosis developed as a complication of distal biceps tendon reattachment through a two-incision technique. The synostosis was excised in all four cases but recurred in two. In each case, the initial reattachment
Autor:
R. D. Beckenbaugh
Publikováno v:
The Journal of Bone and Joint Surgery. British volume. :932-932
Autor:
D M Ilstrup, R D Beckenbaugh
Publikováno v:
The Journal of Bone & Joint Surgery. 60:306-313
A review of 333 consecutive Charnley total hip arthroplasties four to seven years after operation showed that twenty-eight patients had died, and three deaths were directly related to the surgery. The survivors had an average improvement of 46.6 poin
Publikováno v:
Mayo Clinic proceedings. 52(6)
Hip arthroplasty using the Thompson femoral prosthesis with methyl methacrylate fixation was performed on 109 hips in 106 patients. During an average follow-up period of 36 months, 26 patients died. Fifty-one procedures were performed for fresh fract
Publikováno v:
Clinical orthopaedics and related research. (218)
The management of giant cell tumors involving the distal radius has always been a difficult problem. After resection to eradicate a primary or recurrent lesion, transplantation of a nonvascularized fibular autograft was used in 12 patients. Of these