Zobrazeno 1 - 10
of 13
pro vyhledávání: '"R C, More"'
Publikováno v:
Clinical orthopaedics and related research. (282)
The MEC-Ring threaded acetabular component was used in 35 patients for revision of failed cemented hip arthroplasties, and 32 have been observed for two to four years (mean, 2.5 years). With only a short-term follow-up period, 44% of patients have al
Publikováno v:
Clinical Orthopaedics and Related Research. 282:114
The MEC-Ring threaded acetabular component was used in 35 patients for revision of failed cemented hip arthroplasties, and 32 have been observed for two to four years (mean, 2.5 years). With only a short-term follow-up period, 44% of patients have al
Autor:
Keith L. Markolf, R C More
Publikováno v:
The Journal of Bone & Joint Surgery. 70:1020-1031
A Gore-Tex prosthetic ligament was inserted, with an over-the-top femoral placement, into thirteen fresh-frozen cadaver knees as a substitute for the anterior cruciate ligament. The femoral eyelet was screwed into bone and the tibial eyelet was attac
Publikováno v:
The Journal of Bone & Joint Surgery. 66:1460-1465
We recorded anterior-posterior force-versus-displacement curves at 20 and 90 degrees of flexion preoperatively and three years after major ligament reconstruction in patients with documented absence of the anterior cruciate ligament. Patients who had
Publikováno v:
The Journal of bone and joint surgery. American volume. 66(9)
We recorded anterior-posterior force-versus-displacement curves at 20 and 90 degrees of flexion preoperatively and three years after major ligament reconstruction in patients with documented absence of the anterior cruciate ligament. Patients who had
Publikováno v:
Neurophysiology and Standards of Spinal Cord Monitoring ISBN: 9781461283591
Spinal cord impairment is a well recognized but uncommon complication during surgical correction of spinal deformities. Somatosensory evoked potential (EP) monitoring has been used to detect spinal cord impairment intraoperatively, so that immediate
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::d75c107ed9284004350a0bc272f74ad7
https://doi.org/10.1007/978-1-4612-3804-1_27
https://doi.org/10.1007/978-1-4612-3804-1_27
Publikováno v:
Clinical orthopaedics and related research. (233)
Dimethyl sulfoxide (DMSO) is an inorganic compound with many interesting in vitro properties, including the ability to scavenge oxygen-free radicals. DMSO has been used to treat a variety of clinical conditions, especially musculoskeletal trauma, but
Autor:
R C, More, K L, Markolf
Publikováno v:
The Journal of bone and joint surgery. American volume. 70(7)
A Gore-Tex prosthetic ligament was inserted, with an over-the-top femoral placement, into thirteen fresh-frozen cadaver knees as a substitute for the anterior cruciate ligament. The femoral eyelet was screwed into bone and the tibial eyelet was attac
Publikováno v:
Clinical orthopaedics and related research. (242)
Total hip arthroplasty in the young patient remains a considerable challenge. Cemented arthroplasty has an unacceptably high failure rate. Porous ingrowth designs are one alternative, but bone ingrowth is unpredictable, thigh pain is a frequent clini
Publikováno v:
Journal of spinal disorders. 1(1)
Cortical somatosensory evoked potentials (EP) were used for intraoperative monitoring of spinal cord integrity during 158 consecutive cases involving surgical correction of spinal deformities. Using a monitoring technique designed to optimize recordi