Zobrazeno 1 - 10
of 185
pro vyhledávání: '"R Kreuger"'
Publikováno v:
IEEE Transactions on Radiation and Plasma Medical Sciences, 4(1)
Photomultiplier tube (PMT)-based scintillation cameras are predominant in molecular imaging but have the drawback that position estimation is severely degraded near the edges (dead edge effect). This leads to sensitivity losses and can cause severe p
Autor:
J. Huizenga, Freek J. Beekman, Beien Wang, Jarno van Roosmalen, Marlies C Goorden, R. Kreuger
Publikováno v:
Physics in Medicine and Biology, 65(19)
In recent years, breast imaging using radiolabelled molecules has attracted significant interest. Our group has proposed a multi-pinhole molecular breast tomosynthesis (MP-MBT) scanner to obtain 3D functional molecular breast images at high resolutio
Autor:
P. Romero-Lankao, Lucy R. Hutyra, P. J. Marcotullio, R. M. Duren, D. Sailor, C. Kennedy, Z. Zhu, S. Pincetl, K. R. Gurney, M. Betsill, K. V. R. Schäffer, Felix Creutzig, G. Franco, R. Kreuger, D. E. Pataki, K. J. Davis, Mikhail Chester, Sara Hughes
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::89b6274b1db0a798b2d1a3dccd16aab6
https://doi.org/10.7930/soccr2.2018.ch4
https://doi.org/10.7930/soccr2.2018.ch4
Publikováno v:
Physica Medica: an international journal devoted to the applications of physics to medicine and biology, 48
Anger cameras based on monolithic NaI scintillators read out by an array of PMTs are predominant in planar gamma imaging and SPECT. However, position estimation of gamma interactions is usually severely degraded near the edges of the scintillator whi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::462755460f95d741bdb317e28e8a89be
http://resolver.tudelft.nl/uuid:6a79b9f7-ab20-4c1b-8554-687b7de569dd
http://resolver.tudelft.nl/uuid:6a79b9f7-ab20-4c1b-8554-687b7de569dd
Autor:
J. Huizenga, R. Kreuger, Freek J Beekman, Dennis R. Schaart, S. Salvador, Johannes Heemskerk, Marc A N Korevaar, Stefan Seifert
Publikováno v:
Physics in Medicine and Biology. 57:7709-7724
High spatial resolution γ-imaging can be achieved with scintillator readout by low-noise, fast, electron-multiplying charge-coupled devices (EMCCDs). Previously we have shown that false-positive events due to EMCCD noise can be rejected by using the
Autor:
Marlies C Goorden, Nerine J. Cherepy, R. Kreuger, Erik van der Kolk, Pieter Dorenbos, Freek J Beekman, Stephen A. Payne, Jan W T Heemskerk, Zachary M. Seeley, Marc A N Korevaar, S. Salvador
Publikováno v:
Physics in Medicine and Biology. 57:4545-4554
Detection of x-rays and gamma rays with high spatial resolution can be achieved with scintillators that are optically coupled to electron-multiplying charge-coupled devices (EMCCDs). These can be operated at typical frame rates of 50 Hz with low nois
Publikováno v:
IEEE Transactions on Nuclear Science. 59:545-551
We have developed an 80-channel readout system for gamma cameras which acquires PMT signals and stores them in list-mode format on a computer. The system combines low noise and a large signal range to handle PMT signals from a wide range of SPECT and
Publikováno v:
Physics in Medicine and Biology. 54:6549-6563
The potential of tumour tracking for active spot-scanned proton therapy was assessed. Using a 4D-dose calculation and simulated target motion, a tumour tracking algorithm has been implemented and applied to a simple target volume in both homogenous a
Autor:
J. Huizenga, E Seravalli, A.. Simon, J.. Hendrikse, Jacobus M. Schippers, C.W.E. van Eijk, R. Kreuger
Publikováno v:
IEEE Transactions on Nuclear Science. 54:1271-1278
The characterization of a scintillating GEM based gas detector for quality control of clinical radio-therapeutic beams is presented. Photons emitted by the Ar/CF4 gas mixture are detected by means of a CCD camera; in addition, the charge is measured.
Autor:
T.L. van Vuure, F.A.F. Fraga, J.M. Schippers, J.T.M. de Haas, S.T.G. Fetal, C.W.E. van Eijk, R. Kreuger
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 513:42-46
A gaseous scintillation detector consisting of a Ar+CF4 filled GEM and a CCD camera has been investigated for the application as a position sensitive dosimeter in proton-beam radiation therapy. The light yield has been measured as a function of the C