Zobrazeno 1 - 10
of 63
pro vyhledávání: '"R, Decking"'
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 144:380-385
AIM The aim of this study is to report the survival and mid-term results including patient-relevant outcome measures with a small-sized cemented stem (CDH-stem) for the treatment of coxarthrosis secondary to developmental dysplasia of the hip. METHOD
Publikováno v:
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 175:1413-1416
Purpose Presentation of the value of postsurgical computed tomography (CT) to diagnose loosening of uncemented femoral stems. Materials and methods Incremental CT and spiral CT were performed on six femora with implanted uncemented stems after the en
Autor:
R. Meier, Th. Paffrath, M. Bischoff, Chr. Göser, U. Schütz, H. Windhagen, M. Kusma, Carl Joachim Wirth, Johann Neu, S. Weckbach, O. Rühmann, M. Rüger, Th. Mückley, L. von Laer, R. K. Zahn, V. Stein, C. J. Wirth, Ph. T. Funovics, Wolf Mutschler, M. Dominkus, Chr. Lassahn, H. Püschmann, R. Sobottke, W. Mutschler, St. Rammelt, J. Beyer-Westendorf, K. Burghofer, M. Militz, X. Baraliakos, M. Jacob, H. Graßhoff, T. Engelhardt, J. Neu, T. Koy, K. Hofmann-Kiefer, D. Kohn, M. Streibelt, Chr. Reichardt, W. F. Beyer, K.-J. Prommersberger, H. Zwipp, Th. Flörkemeier, Chr. K. Lackner, H. Jansen, M. Flören, A. Eisenschenk, D. Rixen, M. F. Gras, H. Reichel, R. Baumgartner, Hans Püschmann, J. Heisel, H.-P. Bischoff, K. Parsch, Hans-Peter Bischoff, Th. Theodoridis, N. Weiss, J. Krämer, P. Eysel, S. Lenschow, R. Decking, M. Schieker, Th. Berndt, C. Sirtl, R. Kraus, V. Bühren, R. H. Meffert, A. P. Verheyden, B. Bouillon, U. Weber, R. A. Fuhrmann, L. Eden
Publikováno v:
Komplikationen in Orthopädie und Unfallchirurgie: vermeiden – erkennen – behandeln
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::455e03ac7f06d7ab2f64b552cf1a012d
https://doi.org/10.1055/b-002-40827
https://doi.org/10.1055/b-002-40827
Publikováno v:
Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca. 74(3)
A number of studies have reported a significant improvement of the postoperative alignment, when computer-navigated total knee arthroplasty (TKA) was compared with conventional techniques. However, no studies are available on the functional and patie
Publikováno v:
Zeitschrift fur Orthopadie und ihre Grenzgebiete. 144(4)
The aim of this study is to report the survival and mid-term results including patient-relevant outcome measures with a small-sized cemented stem (CDH-stem) for the treatment of coxarthrosis secondary to developmental dysplasia of the hip.33 total hi
Publikováno v:
Zeitschrift für Gastroenterologie. 42
Publikováno v:
RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 175(10)
Presentation of the value of postsurgical computed tomography (CT) to diagnose loosening of uncemented femoral stems.Incremental CT and spiral CT were performed on six femora with implanted uncemented stems after the entire femora were embedded in po
Publikováno v:
Journal of biomedical materials research. Part B, Applied biomaterials. 64(2)
The surfaces of retrieved failed cementless total hip implants made of cobalt-chromium-molybdenum casting alloy and of wrought titanium 6-aluminum 4-vanadium alloy were studied with the use of scanning-electron microscopy (SEM), energy-dispersive X-r
Publikováno v:
Hefte zur Zeitschrift „Der Unfallchirurg“ ISBN: 9783540635734
Hefte zur Zeitschrift „Der Unfallchirurg“
Hefte zur Zeitschrift „Der Unfallchirurg“
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::2aa079b7a196af850751166c55eafbf6
https://doi.org/10.1007/978-3-642-60913-8_51
https://doi.org/10.1007/978-3-642-60913-8_51
Publikováno v:
Medizinische Klinik (Munich, Germany : 1983). 90(8)