Zobrazeno 1 - 10
of 21
pro vyhledávání: '"Qimei Liao"'
Autor:
Kangchu Li, Zenghui Teng, Zhaohui Liu, Yuxing Zhang, Kaiping Long, Qimei Liao, Ansheng Ni, Guirong Ding, Shirong Ma
Publikováno v:
Journal of Immunology Research, Vol 2019 (2019)
Effects of pulsed electromagnetic field (PEMF) on hematology and hematopoiesis might vary with different PEMF parameters. The purpose of this study was to evaluate the possible effects of PEMF exposure at different pulses on hematologic and hematopoi
Externí odkaz:
https://doaj.org/article/1cce2855a1e542139f32f9bf8574ec3b
Autor:
Qimei Liao, Zenghui Teng, Shirong Ma, Gui-Rong Ding, Kangchu Li, Kaiping Long, Ansheng Ni, Zhaohui Liu, Yuxing Zhang
Publikováno v:
Journal of Immunology Research
Journal of Immunology Research, Vol 2019 (2019)
Journal of Immunology Research, Vol 2019 (2019)
Effects of pulsed electromagnetic field (PEMF) on hematology and hematopoiesis might vary with different PEMF parameters. The purpose of this study was to evaluate the possible effects of PEMF exposure at different pulses on hematologic and hematopoi
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 820:54-64
To overcome the oversmoothing drawback in the edge areas when reconstructing few-view CT with total variation (TV) minimization, in this paper, we propose an anisotropic edge-guided TV minimization framework for few-view CT reconstruction. In the fra
Publikováno v:
IEEE Transactions on Biomedical Engineering. 61:1621-1627
X-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging with X-ray. However, challenges remain in dynamic XLCT imaging, where short scan time, good spatial resolution, and whole-body field of view should be
Publikováno v:
SPIE Proceedings.
X-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging with x-ray. It is a dual modality imaging technique based on the principle that some nanophosphors can emit near-infrared (NIR) light when excited by x
Publikováno v:
SPIE Proceedings.
Evaluating spatial resolution is an essential work for cone-beam computed tomography (CBCT) manufacturers, prototype designers or equipment users. To investigate the cross-sectional spatial resolution for different transaxial slices with CBCT, the sl
Publikováno v:
Medical Imaging: Image Processing
Beam hardening, which is caused by spectrum polychromatism of the X-ray beam, may result in various artifacts in the reconstructed image and degrade image quality. The artifacts would be further aggravated for the sparse-view reconstruction due to in
Publikováno v:
2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
To improve the spatial resolution of the image reconstructed by the conventional total variation (TV) algorithm, we propose a prior image based anisotropic edge guided TV minimization (PIEGTV) algorithm for few-view CT reconstruction. In this study,
Publikováno v:
Medical Imaging: Computer-Aided Diagnosis
Image-based computer-aided detection and diagnosis (CAD) has been a very active research topic aiming to assist physicians to detect lesions and distinguish them from benign to malignant. However, the datasets fed into a classifier usually suffer fro
Publikováno v:
Lecture Notes in Computer Science ISBN: 9783319136912
ABDI@MICCAI
ABDI@MICCAI
To find an effective way to quantitatively analyze the thickness variation of human bladder wall under different states, in this paper, we proposed a novel pipeline for thickness measurement, analysis, and mapping of bladder wall based on T2-weighted
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::af9f7f8797e81b1223ca23ba5f29efea
https://doi.org/10.1007/978-3-319-13692-9_24
https://doi.org/10.1007/978-3-319-13692-9_24