Due to the increasing short-circuit current levels in modern power grids, it is planned to install a current limiter based on a high-coupling split reactor in the 500kV power grid to limit the short-circuit current. However, the connection of the cur
Publikováno v:
2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE).
The fault current limiter (FCL) based on high coupling split reactor is a new technology to realize current suppression and current interruption in recent years. This paper introduces the new FCL developed by China Southern Power Grid Corporation for
Autor:
Yuan Zhao, Zhu Lu, Lin Gan, Wenxiong Mo, Kaijian Wu, Wang Yong, Su Haibo, Qiao Shengya, Liu Junxiang
Publikováno v:
Lecture Notes in Electrical Engineering ISBN: 9783030316754
With the rapid development of the power system, the short circuit current level has increased sharply. In order to ensure security, stability and reliable operation of power system, the fault current limiter (FCL) is one of the effective measures to
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::88605ea5faa6151411fb5a545a22e42c
https://doi.org/10.1007/978-3-030-31676-1_141
https://doi.org/10.1007/978-3-030-31676-1_141
Autor:
Ze Guo, Wang Yong, Su Haibo, Lin Gan, Qiao Shengya, Mo Wenxiong, Liu Junxiang, Li Chen, Gu Le, Zhu Lu
Publikováno v:
Lecture Notes in Electrical Engineering ISBN: 9783030316754
Paralleled high-voltage SF6 circuit breakers with a highly coupled split reactor (HCSR) have an excellent interruption performance, because it is expected that this structure could realize the function of automatic current-sharing when the current fl
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::51839353f56b9da26553fb93c8cef925
https://doi.org/10.1007/978-3-030-31676-1_29
https://doi.org/10.1007/978-3-030-31676-1_29
Publikováno v:
ISGT Europe
Successive commutation failure is one of the common faults in multi-infeed HVDC system (MI-HVDC), which has a huge adverse impact on the operation of power systems. Fault current limiter (FCL) is a device that can be used for limiting the risk of suc
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 23:2942-2948
Basin insulators in gas insulated switchgear (GIS) are prone to failure by partial discharge (PD). Insulation diagnosis using gas analysis method has advantages of strong anti-interference ability and high detection precision. This paper reports a ne
Publikováno v:
IOP Conference Series: Materials Science and Engineering. 752:012014
To perfect the application of the fault current limiter in grid and improve the use efficiency, an optimal configuration method of fault current limiter based on multi-objective decision is proposed. Firstly, use rate of current change to select alte
Publikováno v:
2016 IEEE International Conference on High Voltage Engineering and Application (ICHVE).
With the wide use of gas insulated equipment, alternative gas for SF 6 , such as SF 6 /N 2 mixture, has been put forward to reduce the strong greenhouse effect of SF 6 . Gas insulated equipment usually undergoes a wide temperature range. However, lit
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
2016 IEEE International Conference on High Voltage Engineering & Application (ICHVE); 2016, p1-4, 4p