Publikováno v:
IEEE Journal of Emerging and Selected Topics in Power Electronics. 11:850-861
This paper introduces a new modular cascaded multilevel inverter (MLI) which is composed of a cascaded connection of submodules (SMs). The combination of basic cells (BCs) with polarity changer H-Bridge produces the SMs, which is the basis of the int
Publikováno v:
IEEE Transactions on Power Delivery. 37:3447-3457
The safety of converters is key to the stable operation of AC/DC hybrid power grids after AC faults. Thyristor valve current is a direct manifestation of the converter observability, but there are no measuring elements inside the converter, so the th
Publikováno v:
IEEE Transactions on Industrial Electronics. 69:6774-6783
In this paper, a novel modular multilevel dc-dc converter with high power-density potential is proposed based on a cascaded string of voltage source submodules (VSM) merged with a current source submodule (CSM) that is configured to rapidly invert th
Publikováno v:
IEEE Journal of Emerging and Selected Topics in Power Electronics. 10:2210-2222
In this paper, a novel flying capacitor based multilevel topology is presented to minimize the size and cost. The proposed topology can operate in symmetrical as well as asymmetrical configuration of dc sources and produces the 9 level and 25 level o
Publikováno v:
IEEE Transactions on Power Delivery. 37:1161-1170
In this paper, the study initiated in its first part on the traveling waves (TWs) launched by faults on threephase transmission lines is continued, giving major focus to TWs reflection and refraction matrices at line terminations and fault point. By
Publikováno v:
IEEE Journal of Emerging and Selected Topics in Power Electronics. 10:184-195
Dual-inverter fed open-end winding PMSM (OW-PMSM) drive topology can extend the speed range under limited DC bus voltage, but it suffers from the zero-sequence current (ZSC) problem when with common bus configuration. Predictive current control (PCC)
Publikováno v:
IEEE Journal of Solid-State Circuits. 57:546-561
This article reports a single-loop full-rate bang-bang clock and data recovery (BBCDR) circuit supporting a four-level pulse amplitude modulation (PAM-4) pattern. We eliminate both the reference and the separate frequency detector (FD) by deliberatel
Publikováno v:
IEEE Transactions on Power Delivery. 37:619-626
Frequency Response Analysis (FRA) is a comparison based method and is useful to identify the mechanical fault in transformer winding only when the ‘healthy’ or ‘reference’ magnitude response is available. But, in practice, ‘healthy’ respo
Publikováno v:
IEEE Microwave and Wireless Components Letters. 32:169-172
This letter proposes a dual-band high-efficiency rectifier using a GaN transistor. Positive polarity and negative polarity modes are set at $f_{1}$ , and $f_{2}$ , respectively. Then, the rectifier operation at $f_{1}$ and $f_{2}$ is realized upon ad
Publikováno v:
IEEE Journal of Emerging and Selected Topics in Power Electronics. 10:1138-1152
This paper presents a fault diagnosis method in the two-level three-phase voltage source converter (VSC) systems based on the average phase voltage (APV) model without additional sensors or hardware circuits, which can diagnose and locate multiple op