Publikováno v:
Medical Dosimetry. 28:243-253
An innovative (and yet simple) dosimetric model is proposed that provides a semi-analytical solution to the total activity-volume relationship in ultrasound-guided transperineal prostate implant. This dosimetric model is based on 4 simple assumptions
Publikováno v:
Radiation Oncology Investigations. 7:374-381
A simple five-seed assay method was proposed and investigated. A commercial well ion chamber system with an NIST-traceable single-seed calibration constant was used for the single-seed assays. A batch seed holder was used for batch assays. For the fi
Autor:
Plato C. Lee
Publikováno v:
Medical Dosimetry. 21:227-233
Certain fundamental dosimetrical parameters involving the applications of asymmetric jaws were investigated. The nominal accelerating potentials (NAPs) were found to decrease from 5.1 to 4.2 and from 18.0 to 13.4 for the 6 and 18 MV beams, respective
Autor:
Plato C. Lee, Gleen P. Glasgow
Publikováno v:
Medical Dosimetry. 19:141-144
The beam-hardening effects of the wedges on a 6-MV spoiled beam has been studied. The beam quality of all the wedged beams was found to be the same as the open beam. The dmax also stayed unchanged for all the wedges at all field sizes. The relative w
Publikováno v:
Medical physics. 30(10)
This study describes one institution's experience with seed retrieval through the urinary tract and makes recommendations for cystoscopy and urine straining post prostate brachytherapy (PB). 1794 patients from two separate cohorts covering different
Autor:
Glenn P. Glasgow, Plato C. Lee
Publikováno v:
Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 23(2)
In July 1996, Kodak released new film-screen systems with enhanced contrast (EC) for portal localization with megavoltage therapeutic beams. This study presents the generation of general-purpose technique charts for Kodak's new film-screen combinatio
Autor:
Plato C. Lee
Publikováno v:
Medical physics. 24(9)
A quantitative study of the differential beam hardening effect of the flattening filter on the 6-MV beam of Clinac 2100C has been conducted with Monte Carlo simulations using EGS4 code. The fluence-weighted photon energy of the unfiltered beam decrea
Autor:
Plato C. Lee
Publikováno v:
Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 22(1)
Consistent collimator overlaps in field matching with computer-controlled asymmetric x-ray collimators have been observed and investigated. The results indicate that, although this consistent overlapping is small and within manufacturer's +/- 1 mm di
Publikováno v:
International journal of radiation oncology, biology, physics. 29(5)
Purpose: To evaluate a commercial silicone diode dosimeter for a patient dosimetry quality assurance program. Methods and Materials: The diode dosimeter was calibrated against an ion chamber and percentage depth dose, linearity, anisotropy, virtual s
Publikováno v:
Medical physics. 20(3)
A beam spoiler for a 6-MV x-ray beam was designed and spoiled beam dosimetry performed. The spoiled beam quality was similar to that of the unspoiled beam. The percentage depth doses at 5 mm were at least 90% for all field sizes except 4 x 4 cm, whil