Zobrazeno 1 - 10
of 22
pro vyhledávání: '"Piotr Lubicki"'
Autor:
Rohit S. Thute, Himanshu J. Bahirat, Shrikrishna A. Khaparde, Piotr Lubicki, Shankar Kodle, Vikas Dabeer
Publikováno v:
IET Generation, Transmission & Distribution, Vol 13, Iss 10, Pp 1960-1969 (2019)
There is an increase in fault current levels seen by utilities due to grid expansion and the addition of new resources. Installation of superconducting fault current limiter (SCFCL) at transmission voltage levels is being explored to reduce the fault
Externí odkaz:
https://doaj.org/article/77e23854a3c64fe7b0740c12c87fe6a1
Publikováno v:
IET Generation, Transmission & Distribution. 13:1960-1969
There is an increase in fault current levels seen by utilities due to grid expansion and the addition of new resources. Installation of superconducting fault current limiter (SCFCL) at transmission voltage levels is being explored to reduce the fault
Publikováno v:
IEEE Transactions on Power Systems. 33:131-140
With the sustainable growth in the number of new power plants and scale of transmission systems, the probability of the current exceeding the short-circuit rating of circuit breakers increases. A fault current limiter (FCL), which can be used to redu
Publikováno v:
2016 IEEE International Conference on Power System Technology (POWERCON).
With the rapid increase in the demand for power, equipping power systems with distributed energy resources (DERs) has become a trend. In addition, fault current limiters (FCLs) may be installed to prevent the short circuit current from exceeding the
Publikováno v:
2016 IEEE 6th International Conference on Power Systems (ICPS).
With the fast load growth, the grid is pushed to operate near to the limits. The fault current levels at critical substations can overshoot the limits on various equipments like busbars, circuit breakers and transformers. The various conventional rem
Publikováno v:
Biotechnology and Bioengineering. 73:306-312
Electron beam irradiations of aqueous solutions containing 15–30 mg/L of nitrobenzene at 60 kGy dose removed 78% of the contaminant. Three mononitrophenols were detected as by-products of electron beam treatment of nitrobenzene. A mixed culture enr
Publikováno v:
IEEE Transactions on Power Delivery. :1-1
Publikováno v:
SAE Technical Paper Series.
Conference
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Conference
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.