Zobrazeno 1 - 10
of 19
pro vyhledávání: '"Philippe Gédet"'
Publikováno v:
Haschtmann, D; Stoyanov, JV; Gedet, P; Ferguson, SJ (2008). Vertebral endplate trauma induces disc cell apoptosis and promotes organ degeneration in vitro. European spine journal, 17(2), pp. 289-99. Berlin: Springer-Verlag 10.1007/s00586-007-0509-5
There is a major controversy whether spinal trauma with vertebral endplate fractures can result in post-traumatic disc degeneration. Intervertebral discs, which are adjacent to burst endplates, are frequently removed and an intercorporal spondylodesi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::92078bd34c1587d0e25923e00d610e88
http://doc.rero.ch/record/310028/files/586_2007_Article_509.pdf
http://doc.rero.ch/record/310028/files/586_2007_Article_509.pdf
Publikováno v:
Journal of Clinical Periodontology. 37:818-828
Schliephake H, Hefti T, Schlottig F, Gedet P, Staedt H. Mechanical anchorage and peri-implant bone formation of surface-modified zirconia in minipigs. J Clin Periodontol 2010; 37: 818–828. doi: 10.1111/j.1600-051X.2010.01549. Abstract Aim: To test
Autor:
André Busato, Reto Barmettler, Franck Forterre, Katharina Ursula Hediger, Samuel Isler, Johann Lang, Philippe Gédet, Stephen J. Ferguson
Publikováno v:
Veterinary Surgery. 38:874-880
OBJECTIVE: To determine stiffness and load-displacement curves as a biomechanical response to applied torsion and shear forces in cadaveric canine lumbar and lumbosacral specimens. STUDY DESIGN: Biomechanical study. ANIMALS: Caudal lumbar and lumbosa
Publikováno v:
Veterinary Surgery. 38:49-58
Objective— To study the kinematics of cervical spine segment C4–C5 and its association with disc dimensions and the coupled motion (CM) in relation to primary motion (PM). Study Design— Cadaveric biomechanical study. Animals— Cadavers of larg
Publikováno v:
Journal of Biomechanics. 40:1881-1885
Apparatus-induced artifacts may invalidate standard spine testing protocols. Kinematic measurements may be compromised by the configuration of motion capture equipment. This study has determined: (1) the influence of machine design (component frictio
Autor:
Michael Plecko, Rudolf Koch, Stephen J. Ferguson, Michèle Sidler, Alexander Bürki, Philippe Gédet, Jörg A Auer, Ulrich Stoeckle, Daniel Andermatt, Katja Nuss, Robert Frigg, Birthe Pegel, Peter W Kronen, Nico Lagerpusch, Brigitte von Rechenberg, Karina Klein
Background Locking compression plates are used in various configurations with lack of detailed information on consequent bone healing. Study design In this in vivo study in sheep 5 different applications of locking compression plate (LCP) were tested
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b3da4af8f91d7cf49b6e623dd6463d08
https://www.zora.uzh.ch/id/eprint/59138/
https://www.zora.uzh.ch/id/eprint/59138/
Publikováno v:
BMC Veterinary Research, Vol 8, Iss 1, p 139 (2012)
BMC Veterinary Research
BMC Veterinary Research, 8
ResearcherID
BMC Veterinary Research
BMC Veterinary Research, 8
ResearcherID
Background To compare the biomechanical in-vitro characteristics of limited-contact dynamic compression plate (LC-DCP) and locking compression plate (LCP) constructs in an osteotomy gap model of femoral fracture in neonatal calves. Pairs of intact fe
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::01a7e6bf8022873f2dc4e7229ce77761
https://doi.org/10.5167/uzh-71682
https://doi.org/10.5167/uzh-71682
Autor:
Tobias Rudolph, J. Burger, Philippe Büchler, Klaus Scheffler, Jens Kowal, Philippe Gédet, Christoph Reutlinger, Carol-Claudius Hasler
Publikováno v:
Medical Engineering & Physics
The spine is a complex structure that provides motion in three directions: flexion and extension, lateral bending and axial rotation. So far, the investigation of the mechanical and kinematic behavior of the basic unit of the spine, a motion segment,
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::87eea31b4ebc73d79b00168fff802b23
https://hdl.handle.net/11858/00-001M-0000-0013-BC22-7
https://hdl.handle.net/11858/00-001M-0000-0013-BC22-7
Publikováno v:
Journal of clinical periodontology. 37(9)
To test the hypothesis that peri-implant bone formation and mechanical stability of surface-modified zirconia and titanium implants are equivalent.Twelve minipigs received three types of implants on either side of the mandible 8 weeks after removal o
Publikováno v:
The International journal of oralmaxillofacial implants. 24(6)
Resonance frequency analysis (RFA) offers the opportunity to monitor the osseointegration of an implant in a simple, noninvasive way. A better comprehension of the relationship between RFA and parameters related to bone quality would therefore help c