Zobrazeno 1 - 10
of 19
pro vyhledávání: '"Phan‐Tu Vu"'
Publikováno v:
International Transactions on Electrical Energy Systems, Vol 2023 (2023)
In this paper, the development and application of the radial basis function-finite difference (RBF-FD) method and the RBF-finite difference time domain (RBF-FDTD) method for solving electrical transient problems in power systems that are defined by t
Externí odkaz:
https://doaj.org/article/4bed29b53fd14433b09a96bf6ef91bc5
Publikováno v:
IEEE Access, Vol 9, Pp 104572-104581 (2021)
The distribution network reconfiguration (DNR) minimize energy loss is one of the complicated problems and being studied substantially in recent years. Reconfiguration distribution network through the average branch power is a simple and effective me
Externí odkaz:
https://doaj.org/article/c752617ace764cb9b151f81c88d98e55
Autor:
Van Van Huynh, Phong Thanh Tran, Bui Le Ngoc Minh, Anh Tuan Tran, Dao Huy Tuan, Tam Minh Nguyen, Phan-Tu Vu
Publikováno v:
Energies, Vol 13, Iss 24, p 6509 (2020)
The implementation of the sliding mode control (SMC) for load frequency control of power networks becomes difficult due to the chattering phenomenon of high-frequency switching. This chattering problem in SMC is extremely dangerous for actuators used
Externí odkaz:
https://doaj.org/article/83117391146146d08349eda2b9717d70
Publikováno v:
IEEE Access, Vol 9, Pp 104572-104581 (2021)
The distribution network reconfiguration (DNR) minimize energy loss is one of the complicated problems and being studied substantially in recent years. Reconfiguration distribution network through the average branch power is a simple and effective me
Autor:
Bui Le Ngoc Minh, Phong Thanh Tran, Phan-Tu Vu, Anh Tuan Tran, Van Van Huynh, Tam Minh Nguyen, Dao Huy Tuan
Publikováno v:
Energies; Volume 13; Issue 24; Pages: 6509
Energies, Vol 13, Iss 6509, p 6509 (2020)
Energies, Vol 13, Iss 6509, p 6509 (2020)
The implementation of the sliding mode control (SMC) for load frequency control of power networks becomes difficult due to the chattering phenomenon of high-frequency switching. This chattering problem in SMC is extremely dangerous for actuators used
Publikováno v:
A-SSCC
In this paper, we use a non-uniform transmission line model, in which the per-unit length parameters (L(x,t), G(x,t), and C(x,t)) are dependent on space and time proposed by Yaqing Liu et al [4], to simulate lightning-transient voltages of grounding
Publikováno v:
A-SSCC
The Finite-Difference Time-Domain (FDTD) solutions of lightning-induced voltages due to a lightning return stroke on a nearby overhead power line are proposed by Agrawal et al. [4] and Paolone et al. [5]. In this paper, we propose a new numerical met
Publikováno v:
International Transactions on Electrical Energy Systems; 6/27/2023, p1-15, 15p