Zobrazeno 1 - 10
of 77
pro vyhledávání: '"Ph. Grenier"'
Autor:
A. V. Telnov, H. Staengle, M. Legendre, D. Breton, Q. L. Zeng, J.F. Genat, J. Schwiening, S. Ferrag, D. N. Brown, T. Weber, G. Mancinelli, G. Fouque, J. Ocariz, M. J.J. John, G. Lynch, K. Truong, V.G. Shelkov, M. Verderi, M. E. Convery, T. Hadig, L. Gosset, Bl Hartfiel, J. Va'vra, A. Vallereau, M. H. Schune, L. Amerman, A. P. Onuchin, I. Adam, M. Krishnamurthy, A. Salnikov, J.D. Taylor, J. Chauveau, A. M. Lutz, Pierre-Francois Giraud, S.F. Ganzhur, D. Oshatz, Ph. Grenier, G.W. London, C. Beigbeder, A. Lu, D. Aston, B. Mayer, Ch. Yèche, C. Renard, Robert Wilson, S. Dardin, O. Hamon, P. Stiles, Robert Stone, C. Hast, C. De La Vaissiere, G. Vasseur, T. Haas, J. A. Kadyk, M. D. Sokoloff, R. Malchow, Ll.L. Mir, G. R. Bonneaud, E. Roussot, G. Vasileiadis, E. Antokhin, S. M. Spanier, B. T. Meadows, D. McShurley, H. Briand, J.-M. Noppe, P. Besson, W.A. Wenzel, M.-L. Turluer, P. Bourgeois, Andreas Hoecker, R. Reif, Ph Leruste, A. K. Yarritu, Ch Thiebaux, H. M. Lacker, X. Sarazin, H. Kawahara, Stéphane Plaszczynski, M. Zito, P. Bailly, B. N. Ratcliff, M. Long, V. Tocut, R. Cizeron, G. Therin, P. Matricon, S. Schrenk, Daniel E. Hale, Julie Malcles, J. Libby, M. Pripstein, S. W. K. Emery, G. Hamel de Monchenault, J. Lory, A. de Lesquen, H. Lebbolo, M. Doser, A. Gaidot, D. Warner, S. F. Mikhailov, G. Oxoby, A. R. Buzykaev, Lydia Roos, J. Rasson, M. McCulloch, G. De Domenico, I. Ofte, Jan Stark, Sercan Sen, F. Le Diberder, W. Pope, M. Benkebil, F. Martinez-Vidal, Dominik Müller, F. Brochard, B. Zhang, F. Gastaldi, Johann Cohen-Tanugi, T.L. Geld, T. C. Petersen, M. Pivk, G. Wormser, M. Karolak, F. Dohou, S. J. Yellin, Pieter David, R. W. Kadel, R. Aleksan
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2005, 538, pp.281-357. ⟨10.1016/j.nima.2004.08.129⟩
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005, 538, pp.281-357. ⟨10.1016/j.nima.2004.08.129⟩
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2005, 538, pp.281-357. ⟨10.1016/j.nima.2004.08.129⟩
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005, 538, pp.281-357. ⟨10.1016/j.nima.2004.08.129⟩
A new type of ring-imaging Cherenkov detector is being used for hadronic particle identification in the B a B ar experiment at the SLAC B Factory (PEP-II). This detector is called DIRC, an acronym for Detection of Internally Reflected Cherenkov (Ligh
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7dc1207c7abbf88839fefde4e883b948
https://ora.ox.ac.uk/objects/uuid:51d44120-e5a3-4a77-a471-a9f7d2fc8501
https://ora.ox.ac.uk/objects/uuid:51d44120-e5a3-4a77-a471-a9f7d2fc8501
Autor:
Ph. Grenier, A. Malka-Edery
Publikováno v:
The Journal of Physical Chemistry B. 105:6853-6857
The thermal frequency response technique (TFR) has been used to study the diffusion of benzene in NaX zeolite. The corrected diffusion coefficient is found to be independent of loading between 1.5 ...
Publikováno v:
Adsorption. 7:211-219
There have been performed experimental measurements of effective thermal conductivity of silica-gel for a stagnant cylindrical fixed bed under transient and steady state conditions in the presence of dry air at different pressures and for different a
Publikováno v:
Adsorption. 7:5-16
A volume step method measuring the pressure and the adsorbent temperature of an adsorbent-adsorbate system has been developped. It is shown that this method allows the determination of all the relevant parameters of an adsorption process, kinetic as
Publikováno v:
Adsorption. 7:17-25
Measurements have been performed on the influence of a small amount of water on adsorption properties of alkanes (C3 to C6) and olefins (C3 and C4) in NaX zeolite. Adsorption capacity and heat of adsorption have been measured by a Volume Step method.
Publikováno v:
Adsorption. 5:135-143
A Frequency Response Method based on the infrared measurement of the sample temperature has been developed for adsorption kinetics measurements. It consists in modulating the experimental chamber volume at constant frequency. The complex ratio of the
An apparatus for adsorption dynamics studies using infrared measurement of the adsorbent temperature
Publikováno v:
Review of Scientific Instruments. 69:2130-2136
An apparatus has been built for kinetics measurement in adsorption processes. It consists of a variable volume chamber where the adsorbent sample is placed. During the adsorption process the pressure and the sample temperature are measured. The tempe
Publikováno v:
AIChE Journal. 42:700-712
The frequency response method measuring the temperature and pressure of an adsorbent sample determines the mass- and heat-transfer kinetics in adsorbents, especially in zeolites. The temperature of the sample (large crystals or monolayers of pellets)
Publikováno v:
Chemical Engineering Science. 51:269-280
The frequency response behaviour of the adsorbent temperature is analysed in detail for both diffusion in crystals and in biporous pellets. In the case of crystals, it is shown that the temperature frequency response may exhibit very different behavi
Publikováno v:
AIChE Journal. 41:2047-2057
A single-step thermal method is used to measure intracrystalline mass diffusion. Sorption/desorption rates is zeolite samples (large crystals, monolayers of pellets, or even a single pellet) after a pressure of volume step are followed by monitoring