Zobrazeno 1 - 10
of 23
pro vyhledávání: '"Peter Korytár"'
Autor:
Sara Comero, Alberto Cusinato, Silvia Dalla Costa, Bernd Manfred Gawlik, Stephanie K. Bopp, Peter Korytár, Stylianos Kephalopoulos
Publikováno v:
TrAC Trends in Analytical Chemistry. 127:115879
EU bodies, Member State authorities and research organisations make significant efforts to monitor numerous chemicals in various matrices (water, soil, sediment, biota, indoor and outdoor air, feed, food, products, etc.) based on requirements of EU l
Autor:
Sofie Nørager., Peter Korytár, Frans Verstraete, Maria Pilar Aguar Fernandez, Stylianos Kephalopoulos
Publikováno v:
ISEE Conference Abstracts. 2018
Publikováno v:
Environmental Science and Technology, 42(17), 6611-6618
Environmental Science and Technology 42 (2008) 17
Environmental Science and Technology 42 (2008) 17
Comprehensive two-dimensional gas chromatography (GCxGC) coupled with a time-of-flight (ToF) detector allows the separation of many constituents of previously unresolved complex mixtures (UCM) of contaminants in sediment samples. In addition to the p
Publikováno v:
Environmental Science and Technology 42 (2008) 8
Environmental Science and Technology, 42(8), 2845-2852
Environmental Science and Technology, 42(8), 2845-2852
The debromination pathways of seven polybrominated diphenyl ethers (PBDEs) by three different cultures of anaerobic dehalogenating bacteria were investigated using comprehensive two-dimensional gas chromatography (GC × GC). The congeners analyzed we
Publikováno v:
Journal of chromatography: A
Journal of Chromatography. A, Including electrophoresis and other separation methods, 1065(2), 239-249
Journal of Chromatography. A, Including electrophoresis and other separation methods 1065 (2005) 2
Journal of Chromatography. A, Including electrophoresis and other separation methods, 1065(2), 239-249
Journal of Chromatography. A, Including electrophoresis and other separation methods 1065 (2005) 2
The elution order of 126 polybrominated diphenyl ethers (PBDE) was determined for seven different gas chromatographic (GC) stationary phases. The resulting database facilitates selection of the most suitable GC columns for developing a quantitative,
Publikováno v:
Journal of Chromatography. A, Including electrophoresis and other separation methods 1086 (2005) 1-2
Journal of Chromatography. A, Including electrophoresis and other separation methods, 1086(1-2), 29-44
Journal of Chromatography. A, Including electrophoresis and other separation methods, 1086(1-2), 29-44
Separations of 12 compound classes, polychlorinated biphenyls (PCBs), diphenyl ethers (PCDEs), naphthalenes (PCNs), dibenzothiophenes (PCDTs), dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), terphenyls (PCTs) and alkanes (PCAs), toxaphene, organoha
Autor:
Conny Danielsson, P.E.G. Leonards, Peter Korytár, U.A.Th. Brinkman, J. de Boer, Peter Haglund
Publikováno v:
Journal of Chromatography. A, Including electrophoresis and other separation methods, 1038, 189-199
Journal of Chromatography. A, Including electrophoresis and other separation methods 1038 (2004)
Journal of Chromatography. A, Including electrophoresis and other separation methods 1038 (2004)
Comprehensive two-dimensional gas chromatography (GC x GC) with electron-capture detection (ECD) has been optimized for the separation of seventeen 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins and dibenzofurans and 12 dioxin-like polychlorin
Publikováno v:
Journal of Chromatography. A, Including electrophoresis and other separation methods, 994(1-2), 179-189
Journal of Chromatography. A, Including electrophoresis and other separation methods 994 (2003) 1-2
Journal of Chromatography. A, Including electrophoresis and other separation methods 994 (2003) 1-2
Comprehensive two-dimensional gas chromatography (GC x GC) coupled with micro electron-capture and time-of-flight mass spectrometric (TOF-MS) detection has been used to analyse technical toxaphene. An HP-1 x HT-8 column combination yielded highly str
Autor:
Jani Mäkelä, Conny Danielsson, Minna Kallio, Udo A. Th. Brinkman, Menno Brandt, Peter Korytár, René J. J. Vreuls, E. Maria Kristenson, Jan Beens
Publikováno v:
Journal of Chromatography A, 1019(1-2), 65-77. Elsevier
Kristenson, E M, Korytar, P, Danielsson, C, Kallio, M, Brandt, M, Makela, J, Vreuls, R J J, Beens, J & Brinkman, U A T 2003, ' Evaluation of modulators and electron-capture detectors for comprehensive two-dimensional GC of halogenated organic compounds ', Journal of Chromatography A, vol. 1019, no. 1-2, pp. 65-77 . https://doi.org/10.1016/S0021-9673(03)01237-8
Journal of Chromatography. A, Including electrophoresis and other separation methods, 1019(1-2), 65-77
Journal of Chromatography. A, Including electrophoresis and other separation methods 1019 (2003) 1-2
Kristenson, E M, Korytar, P, Danielsson, C, Kallio, M, Brandt, M, Makela, J, Vreuls, R J J, Beens, J & Brinkman, U A T 2003, ' Evaluation of modulators and electron-capture detectors for comprehensive two-dimensional GC of halogenated organic compounds ', Journal of Chromatography A, vol. 1019, no. 1-2, pp. 65-77 . https://doi.org/10.1016/S0021-9673(03)01237-8
Journal of Chromatography. A, Including electrophoresis and other separation methods, 1019(1-2), 65-77
Journal of Chromatography. A, Including electrophoresis and other separation methods 1019 (2003) 1-2
Different cryogenic and a heated GC x GC modulator(s) were evaluated and compared for the analysis of high-boiling halogenated compounds. The cryogenic modulators investigated were: (i) the longitudinally modulated cryogenic system; (ii) the liquid-n
Publikováno v:
Journal of Separation Science. 25:1325-1331
The use of larger volume injection with on-column injection and fast GC commercial instrumentation was evaluated with the model mixture of n-alkanes of a broad range of volatility (C 10 -C 28 ). The presented configuration allows introduction of 40-8