Zobrazeno 1 - 10
of 58
pro vyhledávání: '"Peter H A Mutsaers"'
Autor:
Martijn L L Chatrou, Jack P Cleutjens, Ger J van der Vusse, Ruben B Roijers, Peter H A Mutsaers, Leon J Schurgers
Publikováno v:
PLoS ONE, Vol 10, Iss 11, p e0142335 (2015)
Vascular calcification is associated with poor cardiovascular outcome. Histochemical analysis of calcification and the expression of proteins involved in mineralization are usually based on whole section analysis, thereby often ignoring regional diff
Externí odkaz:
https://doaj.org/article/14a208deb6984307991065de4712e2ba
Publikováno v:
Ultramicroscopy, 190, 12-20. Elsevier
The energy distribution of a high brightness rubidium ion beam, which is intended to be used as the source for a focused ion beam instrument, is measured with a retarding field analyzer. The ions are created from a laser-cooled and compressed atomic
Autor:
R.G.W. van den Berg, A. Rajabi, Peter H. A. Mutsaers, W. F. Toonen, X. F. D. Stragier, O.J. Luiten, P.W. Smorenburg
Publikováno v:
Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1019:165843. Elsevier
The Advanced Continuous-wave Electron (ACE) injector group at the Coherence and Quantum Technology (CQT) group of the Eindhoven University of Technology is developing a GHz repetition-rate electron injector where a low emittance and high repetition-r
Autor:
X. F. D. Stragier, P.W. Smorenburg, Peter H. A. Mutsaers, A. Rajabi, R.G.W. van den Berg, W. F. Toonen, O.J. Luiten
Publikováno v:
Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1013:165678. Elsevier
The Advanced Continuous-wave Electron injector aims to provide accelerator-based light sources with a high repetition rate and high average current electron beam. The injector consists of a DC thermionic gun generating a continuous electron beam, aft
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1013:165651
This paper presents the RF design, thermal calculations and beam dynamics simulations of a compact, high repetition rate, travelling-wave RF photogun operating at the European X-band frequency of 11.994 GHz. The design is based on a CLIC prototype st
Publikováno v:
Applied Physics Letters, 113(16):163104. American Institute of Physics
This paper presents the experimental realization of an ultrafast electron microscope operating at a repetition rate of 75 MHz based on a single compact resonant microwave cavity operating in a dual mode. This elliptical cavity supports two orthogonal
Publikováno v:
Structural Dynamics
Structural Dynamics, Vol 5, Iss 5, Pp 051101-051101-8 (2018)
Structural Dynamics, 5(5):051101. AAPM-American Association of Physicists in Medicine
Structural Dynamics, Vol 5, Iss 5, Pp 051101-051101-8 (2018)
Structural Dynamics, 5(5):051101. AAPM-American Association of Physicists in Medicine
The possibility to perform high-resolution time-resolved electron energy loss spectroscopy has the potential to impact a broad range of research fields. Resolving small energy losses with ultrashort electron pulses, however, is an enormous challenge
Autor:
Jasper F. M. van Rens, Christian Kisielowski, Peter H. A. Mutsaers, Joo Kang, Peter N. Nickias, W. Verhoeven, E. R. Kieft, Steve Rozeveld, Jom Luiten, Alyssa J. McKenna, Bert Freitag, David F. Yancey, Petra Specht
Publikováno v:
Microscopy and Microanalysis. 25:1652-1653
Publikováno v:
Microscopy and Microanalysis. 25:1666-1667
Publikováno v:
Physical Review A : Atomic, Molecular and Optical Physics, 96(5):053412. American Physical Society
A two-step photoionization strategy of an ultracold rubidium beam for application in a focused ion beam instrument is analyzed and implemented. In this strategy the atomic beam is partly selected with an aperture after which the transmitted atoms are