Zobrazeno 1 - 10
of 10
pro vyhledávání: '"Petar Vukelja"'
Publikováno v:
Zbornik Radova: Elektrotehnički Institut "Nikola Tesla", Vol 26, Iss 26, Pp 177-194 (2016)
The goal of this paper is to introduce a procedure for risk assessment of insulation failure due to storm surges. The simulations were carried out in ATP / EMTP software, which allowed the use of the Monte Carlo method for the statistical analysis of
Publikováno v:
Zbornik Radova: Elektrotehnički Institut "Nikola Tesla", Vol 2015, Iss 25, Pp 87-96 (2015)
This paper presents the current state of the overvoltage protection of generator transformers in power plants of the Power Company of Serbia (EPS) and gives a critical overview of their overvoltage protection. Recommendations for the purpose of its c
Publikováno v:
Zbornik Radova: Elektrotehnički Institut "Nikola Tesla", Vol 2012, Iss 22, Pp 185-194 (2012)
This paper presents the results of experimental studies of ground fault currents and overvoltages that occur in the establishment and interruption of ground faults in an isolated part of the 10 kV distribution network, fed to the city of Nis, from fo
Autor:
Jovan Mrvić, Petar Vukelja
Publikováno v:
Zbornik Radova: Elektrotehnički Institut "Nikola Tesla", Vol 2011, Iss 21, Pp 223-239 (2011)
The paper presents the results of research in lightning surge waves and switching overvoltages transferred from a network of 220 kV to the 15.65 kV level of the step-up transformer in HPP 'Bajina Basta'. Analysis of survey results lead to conclusion
Publikováno v:
Facta universitatis - series: Electronics and Energetics. 15:409-418
In this paper experimentally determined temporary over voltages in the electrical power system of Yugoslavia due to: earth faults, load droppings performances with incomplete phases, Ferranti effects, switching-in unloaded transformers, energizations
This paper presents an approach to the insulation co-ordination of electric-power installations in the scope of the continuous operating voltages and temporary overvoltages; this approach opens the possibility to calculate the necessary required with
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0ff839411848ac2e3741e8b707433bac
https://zenodo.org/record/6394146
https://zenodo.org/record/6394146
This paper presents an approach to the calculation of disruptive discharge risk and the reliability parameters for insulations of high-voltage facilities. It starts from overvoltages on individual insulations occurring as the consequence of the relev
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c02af75f8d1dc5f71fd7204493db3d05
https://zenodo.org/record/6397013
https://zenodo.org/record/6397013
Publikováno v:
Electrical Engineering; Jun2006, Vol. 88 Issue 5, p441-446, 6p
Publikováno v:
Electrical Engineering; Jun2006, Vol. 88 Issue 5, p447-452, 6p
Conference
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.