Zobrazeno 1 - 10
of 17
pro vyhledávání: '"Paweł Ratajczyk"'
Autor:
Kemal Tolga Saraçoğlu, Gülten Arslan, Ayten Saraçoğlu, Özlem Sezen, Paweł Ratajczyk, Tomasz Gaszynski
Publikováno v:
BMC Anesthesiology, Vol 24, Iss 1, Pp 1-11 (2024)
Abstract Background Pulse oximetry is a standart of anesthesia for perioperative monitoring. Due to the principles of Hb oxygen dissociation curve, peripheral oxygen saturation has an approximate sensitivity and specificity of 90% for the detection o
Externí odkaz:
https://doaj.org/article/f85fc8647f2143e69c1ea2385a8ff736
Publikováno v:
BMC Emergency Medicine, Vol 23, Iss 1, Pp 1-7 (2023)
Abstract Background Intubation in the case of out-of-hospital cardiac arrest (OHCA) is one of the most difficult procedures for Emergency Medical Services (EMS). The use of a laryngoscope with a dual light source is an interesting alternative to clas
Externí odkaz:
https://doaj.org/article/7a2b3768e6a44edabd896538b44f2051
Autor:
Paweł Ratajczyk, Krzysztof Wasiak, Przemysław Kluj, Bartosz Szmyd, Caridad G. Castillo-Monzón, Tomasz Gaszyński
Publikováno v:
Heliyon, Vol 9, Iss 10, Pp e21127- (2023)
Background: Macintosh laryngoscope is the most widely used laryngoscope for intubation. In some patients, e.g. with flaccid, drooping, aplastic epiglottis, usage of this laryngoscope, or even videolaryngoscopes, may not provide visualization of a glo
Externí odkaz:
https://doaj.org/article/0cca496af4c146408570a49d7e9f1367
Autor:
Paweł Ratajczyk, Przemyslaw Dolder, Bartosz Szmyd, Manuel A. Gomez-Rios, Piotr Hogendorf, Adam Durczyński, Tomasz Gaszyński
Publikováno v:
Healthcare, Vol 12, Iss 4, p 452 (2024)
The aim of the study was to test the hypothesis that the results obtained with three different types of video laryngoscopes (UESCOPE VL-400, I-View, Non-Channeled Aitraq) with and without an endotracheal stylet should be better than the results obtai
Externí odkaz:
https://doaj.org/article/24bd01ce57324772812bf5f6ae1a2c83
Autor:
Tomasz Gaszyński, Manuel Ángel Gómez-Ríos, Alfredo Serrano-Moraza, José Alfonso Sastre, Teresa López, Paweł Ratajczyk
Publikováno v:
Healthcare, Vol 11, Iss 18, p 2468 (2023)
A wide range of airway devices and techniques have been created to enhance the safety of airway management. However, airway management remains a challenge. All techniques are susceptible to failure. Therefore, it is necessary to have and know the gre
Externí odkaz:
https://doaj.org/article/a3de9acddf4f405ea48bfafe8dfe18cd
Autor:
Przemysław Kluj, Anna Fedorczak, Michał Fedorczak, Tomasz Gaszyński, Cezary Kułak, Mikołaj Wasilewski, Mateusz Znyk, Maria Bartczak, Paweł Ratajczyk
Publikováno v:
Healthcare, Vol 11, Iss 6, p 884 (2023)
Background: The COVID-19 pandemic has necessitated changes in the safety protocols of endotracheal intubation at every level of care. This study aimed to compare the first-pass success rates (FPS) and intubation times (IT) of three video laryngoscope
Externí odkaz:
https://doaj.org/article/535755ccfa4943d58cafee37795a2ff3
Publikováno v:
Healthcare, Vol 11, Iss 5, p 661 (2023)
The aim of the study was to evaluate the laryngoscopes Macintosh, Miller, McCoy, Intubrite, VieScope and I-View in simulated out-of-hospital conditions when used by people without clinical experience, and to choose the one that, in the case of failur
Externí odkaz:
https://doaj.org/article/c29e599e1f534feb95a90803b6936478
Publikováno v:
Diagnostics, Vol 12, Iss 7, p 1633 (2022)
Introduction: The aim of the study was to compare the Intubrite laryngoscope and the standard Macintosh blade laryngoscope (MCL) used by persons with no clinical experience in simulated hospital and non-hospital conditions on a manikin model. Materia
Externí odkaz:
https://doaj.org/article/adcbf68bd6264257ad977091a966d6c4
Autor:
Ayten Saracoglu, Gamze Tanirgan Cabakli, Kemal Tolga Saracoglu, Gul Cakmak, Ilhan Erdem, Tumay Umuroglu, Bulent Sacak, Pawel Ratajczyk
Publikováno v:
Diseases, Vol 12, Iss 10, p 255 (2024)
Introduction: Intraoperative fluid management is one of the most important factors affecting optimal perfusion in the microcirculatory area in patients that undergo flap surgery. While insufficient fluid administration in the intraoperative period le
Externí odkaz:
https://doaj.org/article/b11f0385978a4c62bed7cad035641cbd
Autor:
Ceren Önal, Kemal Tolga Saraçoğlu, Ayten Saraçoğlu, Beyza Nur Özkan, Eray Metin Güler, Gülten Arslan, Seçil Azime Karakuş, Yekbun Bulun, Tomasz Gaszynski, Pawel Ratajczyk
Publikováno v:
Biomedicines, Vol 12, Iss 8, p 1652 (2024)
The primary objective of this in vitro study was to prevent the risk of toxicity associated with bupivacaine, widely used in clinical practice, by using magnesium (Mg), a readily available and cost-effective element, as an adjuvant. We hypothesized t
Externí odkaz:
https://doaj.org/article/03adb79b0d0b4e4f8c39f5b95acc94f2