Zobrazeno 1 - 10
of 29
pro vyhledávání: '"Paul F Walter"'
Publikováno v:
Catheterization and Cardiovascular Diagnosis. 39:181-184
A case is presented illustrating the association of spontaneous coronary vasospasm with sudden death. Serial angiography and challenge with methyl-ergonovine were performed to document the effectiveness of medial therapy. The use and safety of ergono
Autor:
Jonathan J. Langberg, A. Gregory Deam, M. Erick Burton, Paul F. Walter, Kevin McTeague, Wolfgang M. Hartung
Publikováno v:
Pacing and Clinical Electrophysiology. 18:2017-2021
Temperature monitoring during radiofrequency catheter ablation is useful but requires specialized equipment that is not generally available. Previous studies have shown that impedance characteristically decreases as the result of heating at the elect
Publikováno v:
Clinical EEG and neuroscience. 42(3)
It is well established that convulsive movements often accompany syncopal events yet many patients with these clinical features are misdiagnosed with seizures and often referred to epilepsy centers because they are refractory to treatment with antico
Publikováno v:
Circulation. 118
We are grateful for J.L. Sullivan’s interest in and comments regarding our article.1 Clearly, the use of polyethylene gloves is an important constraint to our experiments (We mention this in the article more than once). However, such gloves are a p
Publikováno v:
Circulation. 117(19)
Background— Brief interruptions in chest compressions reduce the efficacy of resuscitation from cardiac arrest. Interruptions of this type are inevitable during hands-off periods for shock delivery to treat ventricular tachyarrhythmias. The safety
Publikováno v:
Circulation. 116
Background: During cardiopulmonary resuscitation, the need for rescuers to stand clear before a shock is delivered invariably interrupts chest compressions. Brief interruptions like these reduce the efficacy of defibrillation in animal models. Curren
Autor:
Charn Sathavorn, David B. De Lurgio, Angel R. Leon, Fernando Mera, Jonathan J. Langberg, Paul F. Walter
Publikováno v:
The American Journal of Cardiology. 79:1409-1411
Severe abrasion of implantable cardioverter-defibrillator leads is frequently found during abdominal generator replacement and occasionally results in lead system failure. Careful inspection of leads at the time of generator replacement will identify
Publikováno v:
Pacing and Clinical Electrophysiology. 18:2106-2108
Patients with the Wolff-Parkinson-White (WPW) syndrome have preexcited tachycardia as the result of atrial arrhythmias or antidromic reentry. This article describes a patient with persistent wide complex tachycardia due to abnormal automaticity in th
Autor:
Jonathan J. Langberg, David DeLurgio, Fernando Mera, Charn Sathavorn, Andreas Bollmann, Paul F. Walter, Alexandra Marx
Publikováno v:
Pacing and clinical electrophysiology : PACE. 22(1 Pt 2)
BACKGROUND The miniaturization of implantable cardioverter defibrillators (ICDs) has made pectoral implantation possible. However, postoperative pain following the procedure has not been systematically studied. The aim of the current study was to pro
Publikováno v:
The American journal of cardiology. 80(2)
Intracardiac echocardiography was used to evaluate posteroseptal space anatomy in patients with atrioventricular nodal reentrant tachycardia compared with patients with other mechanisms of tachycardia. The posteroseptal space was found to be signific