Hua Tian, Paul Blenkinsopp, Sadia Sheraz, Nicholas Winograd, John C. Vickerman, Peter J. Cumpson
Publikováno v:
Analytical Chemistry. 91:9058-9068
Previous studies have shown that the use of a 20 keV water cluster beam as a primary beam for the analysis of organic and bio-organic systems resulted in a 10-100 times increase in positive molecular ion yield for a range of typical analytes compared
Autor:
Valerian E. Kagan, Paul Blenkinsopp, Nicholas Winograd, Simon C. Watkins, Andrew A. Amoscato, Louis J. Sparvero, Hülya Bayır, Hua Tian
Publikováno v:
Angewandte Chemie International Edition. 58:3156-3161
Millions of diverse molecules constituting the lipidome act as important signals within cells. Of these, cardiolipin (CL) and phosphatidylethanolamine (PE) participate in apoptosis and ferroptosis, respectively. Their subcellular distribution is larg
The data contained in this repository has been used to produce the 'Single Ion Implantation of Bismuth' paperDOI: 10.1002/pssa.202000237. We present the results from a focused ion beam instrument designed to implant single ions with a view to the fab
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od______2659::c4fa8172d75be33cf309c94860e5a421
https://zenodo.org/record/3935930
https://zenodo.org/record/3935930
Publikováno v:
International Journal of Mass Spectrometry. 377:591-598
There is considerable excitement surrounding the application of gas cluster ion beams (GCIBs) for SIMS analysis in order to study organic materials and biological samples such as cells and tissues. These ion beams, that often comprise several thousan
Autor:
Zbigniew Postawa, Andreas Wucher, Barbara J. Garrison, Nicholas Winograd, Paul Blenkinsopp, Daniel A. Brenes
Publikováno v:
Surface and Interface Analysis. 45:50-53
Recent experimental measurements and calculations performed by molecular dynamics computer simulations indicate, for highly energetic C60 primary ions bombarding molecular solids, the emission of intact molecules is unique. An energy- and angle-resol
Publikováno v:
Surface and Interface Analysis. 43:506-509
We have built a mass spectrometer which utilizes a new method of time-of-flight analysis to provide rapid data acquisition with simultaneous high spatial resolution and high mass resolution. The mass analysis is performed by sampling the secondary be
Autor:
Patrick Philipp, John S. Fletcher, Tina B. Angerer, Tom Wirtz, Sanna Sämfors, Paul Blenkinsopp
Publikováno v:
Analytical chemistry. 87(19)
In secondary ion mass spectrometry (SIMS), the beneficial effect of cesium implantation or flooding on the enhancement of negative secondary ion yields has been investigated in detail for various semiconductor and metal samples. All results have been
Autor:
Daniel A, Brenes, Zbigniew, Postawa, Andreas, Wucher, Paul, Blenkinsopp, Barbara J, Garrison, Nicholas, Winograd
Publikováno v:
Surface and interface analysis : SIA. 45(1)
Recent experimental measurements and calculations performed by molecular dynamics computer simulations indicate, for highly energetic C60 primary ions bombarding molecular solids, the emission of intact molecules is unique. An energy- and angle-resol
Publikováno v:
Applied Surface Science. 252:7304-7307
C 60 ion beams are being used in a widening variety of analytical applications. The interaction of the C 60 molecule with most sample surfaces differs markedly from that of an atomic ion beam, leading to elevated sputter yields and ion yields. A furt
Autor:
John C. Vickerman, Nicholas P. Lockyer, Daniel Eduardo Weibel, Steve Wong, Paul Blenkinsopp, Rowland Hill
Publikováno v:
Analytical Chemistry. 75:1754-1764
A buckminsterfullerene (C60)-based primary ion beam system has been developed for routine application in TOF-SIMS analysis of organic materials. The ion beam system is described, and its performance is characterized. Nanoamp beam currents of C60+ are